Air Conditioning -> Checking the Efficiency of the Air Conditioning System for Your Citroen C6 4 Door First Generation (2005-2012)

CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM  
Equipment: EXXOTest  
Tooling (tools and Equipment flash).  
Equipment:VALEO  
Tooling.  
Exxoclim  
: 2.4.2-1.  
Clim test 2  
Method of use  
: 4372-T.  
Method of use  
: See instructions.  
: See instructions.  
E5AP2N5D  
E5AP2N4D  
209  
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM  
Testing procedure.  
Checking.  
Position the equipment - Exxoclim or Clim test 2 - (see instructions).  
Preliminary operations.  
Close all the front air vents.  
Start the engine.  
Open the front air vent.  
Activate the «air conditioning» control.  
Position the air distribution control to «frontal flow».  
Activate the «air recirculation» control.  
Positions of the air conditioning controls:  
- Temperature control on maximum cold (LH and RH).  
- Blower control in maximum speed position.  
Let the air conditioning operate for 5 minutes.  
210  
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM  
Reminder (for information)  
Under-cooling.  
The under-cooling represents the difference between the condensation temperature and the aircon fluid temperature at the aircon condenser outlet.  
The under-cooling gives the quantity of aircon fluid (in the liquid state) in the air conditioning circuit.  
Values for under-cooling (SR).  
Values  
SR < 2°C  
Origins  
Solutions  
Lack of aircon fluid in the aircon condenser  
Lack of aircon fluid in the aircon condenser  
Correct quantity  
Add some aircon fluid  
2°C < SR <4°C  
4°C < SR < 10°C/12°C  
SR > 10°C/12°C  
SR > 15°C  
Excess aircon fluid in the aircon condenser  
Remove some aircon fluid  
Over-heating.  
The over-heating represents the difference between the aircon fluid temperature at the evaporator outlet and the evaporation temperature.  
The over-heating gives the quantity of aircon fluid (in the liquid state) in the air conditioning circuit  
Values for over-heating (SC).  
Values  
2° < SC < 15°C  
SC > 15°C  
SC < 2°C  
Origins  
Solutions  
Correct quantity  
Lack of aircon fluid in the cooling circuit  
Excess aircon fluid in the cooling circuit  
Add some aircon fluid  
Remove some aircon fluid  
Blown air temperature.  
The blown air temperature should be between 2°C and 10°C.  
211  
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM  
Aircon circuit diagnosis table (for information)  
Principal problem  
Symptom  
Possible causes  
Aircon compressor clutch  
Lack of aircon fluid in the aircon circuit  
Aircon pressostat  
The clutch of the aircon compressor does not  
engage, or disengages suddenly  
Aircon evaporator sensor  
Electrical circuit (wiring, fuses, etc.)  
Auxiliaries drive belt  
The aircon compressor does not turn  
or stops suddenly  
Aircon compressor  
The clutch of the aircon compressor remains  
engaged and stops suddenly  
Filtering and drying cartridge  
Aircon pressure reducer  
Leak of aircon fluid  
Aircon compressor clutch  
212  
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM  
Aircon circuit diagnosis table (for information)  
Principal problem  
Symptom  
Possible causes  
Incorrect adjustment of the aircon compressor  
clutch  
The clutch of the aircon compressor  
remains engaged  
Aircon fluid quantity  
Aircon compressor defective  
Lack of aircon fluid in the aircon circuit  
Aircon compressor valves defective  
Aircon compressor clutch  
The aircon compressor makes an abnormal  
noise  
The clutch of the aircon compressor  
remains engaged and slips  
Auxiliaries drive belt  
213  
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM  
Aircon circuit diagnosis table (for information)  
Principal problem  
Symptom  
Possible causes  
Aircon pressure reducer defective  
Duct clogged  
Low pressure and high pressure too high  
Low pressure too high and high pressure too low Aircon compressor seal defective  
Aircon evaporator sensor defective  
Low pressure too low and high pressure too high Aircon pressure reducer jammed  
too high  
Abnormal levels of pressure  
Filtering and drying cartridge obstructed  
Duct clogged  
Duct clogged  
Aircon pressure reducer jammed  
Low pressure and high pressure too low  
Lack of aircon fluid in the aircon circuit  
Aircon compressor defective  
214  
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM  
Aircon circuit diagnosis table (for information)  
Principal problem  
Symptom  
Possible causes  
Low pressure normal and high pressure too high Presence of air in the aircon circuit  
Aircon pressostat defective  
Low pressure normal and high pressure too low  
Evaporator sensor defective  
Low pressure too high and high pressure normal Aircon pressure reducer jammed open  
Filtering and drying cartridge saturated or  
Abnormal levels of pressure  
Low pressure too low and high pressure normal  
clogged  
Aircon pressure reducer iced up  
Lack of aircon fluid  
Under cooling too weak  
Air conditioning operating in  
back-up mode  
Excess aircon fluid  
Under cooling excessive  
Presence of air in the aircon circuit  
Filtering and drying cartridge clogged  
NOTE: In all cases, measure the excessive heating (SC) and the blow air temperature.  