FILLING AND BLEEDING THE SUSPENSION CIRCUITS (continued)
Carry out the following operations
Consequences
1
2
3
LHM fluid level to the max. mark.
Loosen the pressure regulator release screw.
Start the engine.
Tighten and slacken the pressure regulator release screw several
times, then retighten it.
4
Priming of the high pressure (HP) pump.
5
6
Height control set to «HIGH» position.
Wait for the vehicle to rise fully.
LHM fluid topped up.
Top up the level : engine running, vehicle in the high position.
260