Air conditioning system -> 2.2 Connecting air conditioner service station to refrigerant circuit for Your Volkswagen Cc 4 Door Second Generation (2012-2017)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
Contaminated refrigerant can change the way in which the air  
conditioning system works and / or permanently damage com‐  
ponents of the refrigerant circuit.  
Mixtures of different refrigerants (e.g. R1234yf refrigerant with  
an unknown quantity of R134a refrigerant) may not be filled in  
a vehicle that has been given type approval for R1234yf re‐  
frigerant.  
Important instructions for working with air conditioner service sta‐  
tion  
To operate the air conditioner service station ( air conditioner  
service station currently available ⇒ Workshop equipment and  
special tools catalogue ), the following must be observed:  
lk  
♦ The fitted filter and dryer must be renewed at the latest when  
the operational time specified in the related operating instruc‐  
tions has been reached.  
♦ If an air conditioner service station is also used to clean (flush)  
the refrigerant circuit, the dryer and filter installed in the system  
must be replaced at shorter intervals ⇒ page 124 .  
♦ Only refrigerant oils that are approved for the vehicle-specific  
refrigerant circuit may be filled in the reservoir (pour the re‐  
frigerant oil directly into the refrigerant circuit if necessary) ⇒  
Electronic parts catalogue .  
♦ Depending on the version of air conditioner service station and  
the measures to be performed, there is a minimum volume of  
refrigerant, refrigerant oil and UV leak detection additive that  
must be in the respective supply reservoirs of the air condi‐  
tioner service station ⇒ Operating instructions air conditioner  
service station  
In the event of any doubt regarding the composition of the refrig‐  
erant extracted from the refrigerant circuit, the extracted refriger‐  
ant must not be re-used even after it has been cleaned in the air  
conditioner service station  
⇒ “2.3 Performing gas analysis of refrigerant”, page 134 .  
♦ If the wrong refrigerant has been accidentally poured in the air  
conditioner service station , it must be emptied  
⇒ “2.4 Emptying refrigerant circuit”, page 137 and  
⇒ “2.2 Connecting air conditioner service station to refrigerant  
circuit”, page 131 . The system may also need to be cleaned,  
including renewal of the filters, dryers and refrigerant oil.  
♦ Contaminated refrigerant, e.g. in Germany, can be returned to  
the supplier in so-called recycling cylinders for analysis, pro‐  
cessing or environmentally-compatible disposal (in other  
countries, different or additional regulations may apply)  
⇒ “6.2.17 Returning contaminated R1234yf refrigerant for  
analysis, processing or disposal”, page 25 .  
2.2  
Connecting air conditioner service sta‐  
tion to refrigerant circuit  
Connecting  
Depending on the type of equipment chosen, there may be  
variations in the required procedure; therefore always follow  
the user's manual for the equipment being used.  
2. Working with air conditioner service station  
131  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
The procedure described in the instruction manual for your air  
conditioning service station is to be followed ⇒ Operating instruc‐  
tions air conditioner service station .  
The charging hoses must only be connected according to the fol‐  
lowing work procedure to prevent air or moisture from entering  
the refrigerant circuit:  
– On vehicles with high-voltage system, switch off “stationary air  
conditioning” function (deactivate)⇒ Owner's Manual and ⇒  
Operating instructions of infotainment / MMI .  
– Switch off ignition.  
– Connect the air conditioner service station to the power sup‐  
ply.  
– Switch on the air conditioner service station and bring it into  
operation as described in the instructions ⇒ Operating in‐  
structions air conditioner service station .  
lk  
– Unscrew the sealing caps from the service connections (see  
vehicle-specific refrigerant circuit) ⇒ Heating, air conditioning;  
Rep. gr. 87 ; Refrigerant circuit (vehicle-specific workshop  
manual).  
– Evacuate the charge hoses if necessary.  
– Check service connections of refrigerant circuit for contami‐  
nation or corrosion, clean if necessary.  
Note  
Dirt or a rough surface on the service connections caused by cor‐  
rosion can cause damage to the seals and thereby premature  
failure of the quick-release couplings.  
– Fit quick-release couplings to the service connections of the  
refrigerant circuit.  
NOTICE  
Risk of damage to the air conditioner compressor or air condi‐  
tioner service station.  
Opening the valves with the air conditioning system switched  
on can cause a short circuit between the high pressure and low  
pressure side.  
– Never open valves on the high pressure or low pressure side  
with the air conditioning system switched on.  
– Turn the handwheel of the quick-release coupling adapter on  
the low pressure side no further than necessary to completely  
open the service connection (observe pressure gauge; do not  
over-tighten valve).  
– Perform a gas analysis using the air conditioner service station  
(only necessary if refrigerant needs to be extracted or pres‐  
sures in the refrigerant circuit need to be checked)  
⇒ “2.3 Performing gas analysis of refrigerant”, page 134 .  
132  
Rep. gr.87 - Air conditioning system  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
Connect the gas analysis device or air conditioner service station  
to the refrigerant circuit as instructed to do so, and bring it into  
operation ⇒ Operating instructions of gas analysis device ,  
⇒ page 131 and / or ⇒ Operating instructions air conditioner  
service station .  
lk  
If during the gas analysis it is found that the refrigerant in the cir‐  
cuit meets the specifications:  
– Turn the handwheel of the quick-release coupling adapter on  
the high pressure side no further than necessary to completely  
open the service connection (observe pressure gauge; do not  
over-tighten valve).  
– Perform the measures as required on the refrigerant circuit  
using the air conditioner service station .  
Note  
If, during the gas analysis, it is found that the R1234y refrig‐  
erant is contaminated, extract the refrigerant from the refrig‐  
erant circuit and send it back e.g. to your gas supplier for  
processing (or disposal)  
⇒ “2.13 Filling contaminated refrigerant in a recycling cylinder  
for analysis, processing or disposal”, page 161 ,  
⇒ “6.2.17 Returning contaminated R1234yf refrigerant for  
analysis, processing or disposal”, page 25 and  
⇒ “6.1 Basics of air conditioning technology”, page 16 .  
Should there be no means of doing this, extract the contami‐  
nated refrigerant immediately from the refrigerant circuit of the  
vehicle and collect in a recycling cylinder. Unscrew (close) the  
handwheel of the quick release coupling adapter on the low  
pressure side, switch off the air conditioner service station  
(and isolate from the power supply if necessary). Then sepa‐  
rate the quick release coupling adapter on the low pressure  
side from the vehicle. The quick release coupling adapter on  
the low pressure side must then be separated - e.g. with a  
suction hose from the workshop extraction unit - from the  
charge hose for the air conditioner service station and the  
contaminated refrigerant allowed to flow out of the charge  
hose into the extraction hose of the workshop extraction unit.  
To restore operational readiness of the air conditioner service  
station , reinstall the quick release coupling adapter on the low  
pressure side on the charge hose for the air conditioner serv‐  
ice station and evacuate using the air conditioner service  
station as instructed to do so in the relevant operating instruc‐  
tions ⇒ Operating instructions air conditioner service station .  
– Perform the measures as required using the air conditioner  
service station .  
⇒ “2.3 Performing gas analysis of refrigerant”, page 134  
⇒ “2.4 Emptying refrigerant circuit”, page 137 .  
⇒ “2.5 Evacuating refrigerant circuit”, page 140 .  
⇒ “2.6 Charging refrigerant circuit”, page 146 .  
⇒ “2.8 Switching off air conditioner service station and sepa‐  
rating from refrigerant circuit”, page 151  
⇒ “2.9 Charging refrigerant in reservoir”, page 153 .  
⇒ “2.10 Emptying air conditioner service station”, page 154 .  
2. Working with air conditioner service station  
133  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
⇒ “2.14 Checking pressures”, page 170  
2.3  
Performing gas analysis of refrigerant  
Note  
For operation of the air conditioning system, it is important that  
the refrigerant used has a certain degree of purity.  
Contamination with other refrigerants or gases can cause  
damage and thereby failure of the air conditioning system.  
Contaminated refrigerant must be returned as gas of unknown  
composition e.g. to your gas supplier for processing (or dis‐  
posal) in accordance with legislative requirements ⇒ VW /  
Audi-ServiceNet .  
To prevent liquid components (e.g. droplets of refrigerant oil)  
in the extracted refrigerant gas from falsifying the result of the  
gas analysis, separators (filters) are installed in the gas anal‐  
ysis device that separate these droplets of liquid. Renew  
separators in accordance with specifications of gas analysis  
device or operating instructions of air conditioner service sta‐  
tion ⇒ Operating instructions of gas analysis device or ⇒  
Operating instructions of air conditioner service station .  
All vehicles  
– Connect the gas analysis device or air conditioner service sta‐  
tion to the refrigerant circuit as instructed to do so, and bring  
it into operation ⇒ Operating instructions of gas analysis de‐  
vice ,  
⇒ “2.2 Connecting air conditioner service station to refrigerant  
circuit”, page 131 and / or ⇒ Operating instructions air condi‐  
tioner service station .  
lk  
– Perform the gas analysis as per the operating instructions.  
Note  
A faulty gas analysis is possible from air in the refrigerant ho‐  
ses or non-observance of the procedure for gas analysis as  
detailed in the operating instructions.  
Carefully follow the operating instructions of the gas analysis  
device / air conditioner service station .  
Evacuate refrigerant hoses of the air conditioner service sta‐  
tion before connecting the service couplings to the refrigerant  
circuit / gas cylinder with R1234yf refrigerant hose (see oper‐  
ating instructions of gas analysis device / air conditioner serv‐  
ice station  
⇒ “2.3 Performing gas analysis of refrigerant”, page 134 .  
The gas analysis may provide the following results:  
♦ The R1234yf refrigerant complies with the specifications, the  
planned measures may be performed with the air conditioner  
service station .  
♦ A fault occurred during the gas analysis. The fault is to be in‐  
vestigated and rectified after which the gas analysis must be  
repeated.  
♦ The analysed R1234yf refrigerant does not comply with the  
specifications, the analysed refrigerant must be extracted as  
refrigerant of unknown composition and returned e.g. to your  
gas supplier for processing (or disposal)  
134  