Air conditioning system with refrigerant R134a - Edition 10.2014  
Vehicle Adapters re‐  
Adapters required for Miscella‐  
quired for refrig‐ refrigerant pipes to re‐ neous  
erant pipes to air ceiver and second  
conditioner com‐ evaporator  
pressor  
ond  
evap‐  
orator  
– After  
purg‐  
ing, in‐  
stall a  
new  
lk  
ex‐  
pan‐  
sion  
valve.  
Transporter 2010; Multivan 2010; California 2010; Caravelle  
2010;  
Note  
On vehicles with a 2nd evaporator, the front and rear refrigerant  
circuit must be rinsed separately. The front refrigerant circuit must  
be sealed with sealing adapter - VAS 6338/5- and sealing adapter  
- VAS 6338/11- .  
112  
Rep. gr.00 - Technical data  
lk  
Amarok 2011 ➤ , Beetle 2012 ➤ , Bora 1999 ➤ , CC 2010 ➤ , CC 2012 ➤ , ...  
Air conditioning system with refrigerant R134a - Edition 10.2014  
Vehicle Adapters re‐  
Adapters required for Miscella‐  
quired for refrig‐ refrigerant pipes to re‐ neous  
erant pipes to air ceiver and 2nd evapo‐  
conditioner com‐ rator  
pressor  
Trans‐ ♦ Low-pres‐  
– Remove dryer car‐ – Install  
porter  
sure side  
adapter -  
VAS  
tridge and seal re‐  
ceiver.  
adapt‐  
er -  
2010 ►,  
Multivan  
2010 ►,  
Califor‐  
nia 2010  
►, Cara‐  
velle  
– After flushing, in‐  
stall a new dryer  
cartridge.  
VAS  
6338/  
56- in  
place  
of ex‐  
pan‐  
sion  
6338/12-  
♦ High-pres‐  
sure side  
♦ Sealing adapter -  
VAS 6338/5- for  
front refrigerant cir‐  
cuit.  
adapter -  
VAS 6338/3-  
2010 ►  
valve  
(or a  
drilled  
out  
♦ Sealing adapter -  
VAS 6338/11- for  
front refrigerant cir‐  
cuit.  
ex‐  
pan‐  
sion  
♦ Low-pressure line  
for second evapo‐  
rator adapter - VAS  
6338/3-  
valve  
pa  
ge 71 )  
♦ High-pressure line  
for second evapo‐  
rator adapter - VAS  
6338/4-  
– Re‐  
move  
and  
drill  
open  
ex‐  
pan‐  
sion  
valve  
for  
rear  
evap‐  
orator  
pa  
ge 71 .  
– After  
purg‐  
ing, in‐  
stall a  
new  
ex‐  
pan‐  
sion  
valve.  
Crafter 2006; LT 2 as of 1997  
Note  
On vehicles with a 2nd evaporator, the front and rear refrigerant  
circuit must be rinsed separately. The front refrigerant circuit must  
be sealed with sealing adapter - VAS 6338/5- and sealing adapter  
- VAS 6338/11- .  
7. Clearing refrigerant circuit of contaminants  