1996-2006 Volkswagen LT Van Detectingleaksinrefrigerantcircuit -> 6.2 Searching for leaks... using leak detector V.A.G 1796 User Manual
MyCarUserManual.com
USER MANUALS FOR EVERY MAKE & MODEL

Detectingleaksinrefrigerantcircuit -> 6.2 Searching for leaks... using leak detector V.A.G 1796 for Your Volkswagen LT Van Second Generation (1996-2006)

Amarok 2011 ➤ , Beetle 2012 ➤ , Bora 1999 ➤ , CC 2010 ➤ , CC 2012 ➤ , ...  
Air conditioning system with refrigerant R134a - Edition 10.2014  
– Evacuating refrigerant circuit if necessary ⇒ page 49  
– Evacuate refrigerant circuit and observe the vacuum gauge  
over a period of hours. Charging may be done only when vac‐  
uum is maintained.  
6.2  
Searching for leaks in refrigerant circuits  
using leak detector - V.A.G 1796-  
lk  
Note  
Small leaks can be detected with, for example, an electronic leak  
detector.  
– Evacuate refrigerant circuit using an air conditioner service  
station ⇒ page 50 .  
Note  
If a larger leak is detected during the evacuation process, de‐  
termine cause and rectify as described ⇒ page 50 .  
If during the evacuation process no leak is detected or a very  
small leak is detected that but cannot be located, proceed as  
follows ⇒ page 56 .  
Refrigerant gas is quickly dispersed by air motion. Therefore  
drafts must be avoided during a search for leaks.  
If the refrigerant circuit is completely empty, charge with about  
10% of refrigerant capacity (sticker R134a or vehicle-specific  
workshop manual).  
Leak detection:  
– Prepare leak detector for operation according to its operating  
instructions.  
– Always hold probe tip under location of suspected leak.  
If the rate of clicks rises or a howl occurs, depending on model, a  
leak has been found (see operating instructions for leak detector).  
58  
Rep. gr.00 - Technical data  

Related Topics