Advertisement

Advertisement

Auxiliary air heater -> 7.10 Removing and installing glow plug for heater Q9 for Your Volkswagen Transporter Van Sixth generation (2015-2021)

Transporter 2020 ➤  
Auxiliary heater - Edition 04.2020  
7.9  
Removing and installing burner unit  
Special tools and workshop equipment required  
♦ Torque wrench - V.A.G 1410A-  
Removing  
– Remove combustion air blower 2 - V385- ⇒ page 47 .  
– Unscrew bolts -2-.  
Note  
Combustion chamber -1- is removed along with glow plug for  
heater - Q9- and fuel pipe.  
– Pull out combustion chamber -1-.  
Installing  
Install in reverse order of removal, observing the following:  
– Renew seal between combustion chamber -1- and heat ex‐  
changer.  
Note  
When reassembling, use the rubber grommets for the wiring har‐  
ness of the glow plug for heater - Q9- and fuel pipe as a guide.  
– Insert combustion chamber -1-.  
– Screw in bolts -2- loosely.  
– Tighten bolts -2- alternately in diagonal sequence to specified  
torque.  
Specified torques  
Component  
Bolts -2-  
Specified torque  
6.5 Nm  
7.10  
Removing and installing glow plug for  
heater - Q9-  
Note  
Glow plug with flame monitor - Q9- is activated immediately  
after activation and switched off again about 1 minute after a  
flame has been detected.  
The maximum glow period for the auxiliary air heater is 150  
seconds.  
When heater unit is switched off, glow plug with flame monitor  
- Q9- is switched back on again during the 4 minute run-on  
time to burn off all fuel.  
It is essential to check the mantle for carbonised deposits and  
damage if glow plug with flame monitor - Q9- is renewed.  
Removing  
– Remove auxiliary air heater ⇒ page 36 .  
7. Auxiliary air heater  
45  
Transporter 2020 ➤  
Auxiliary heater - Edition 04.2020  
– Release locking tabs -1-.  
– Swing cover -2- in direction of -arrow-, and detach it.  
– Pull grommet -3- out of lower casing -1-.  
– Disconnect electrical connector -2-.  
– Lever out grommet -4- with a screwdriver.  
– Remove glow plug for heater - Q9- .  
Installing  
Install in reverse order of removal, observing the following:  
Note  
Make sure that the locking element of the electrical connector for  
the glow plug for heater - Q9- points towards the combustion air  
blower 2 - V385- .  
7.11  
Removing and installing flame monitor -  
G64- and combination sensor  
Note  
The combination sensor comprises the flame monitor - G64- and  
overheating sensor - G189- in one component.  
Removing  
– Remove auxiliary air heater ⇒ page 36 .  
– Release locking tabs -2-.  
– Swing cover -1- in direction of -arrow-, and detach it.  
46  
Rep. gr.82 - Supplementary heating