Fuel supply -> 4.2 Removing and installing metering pump V54 for Your Volkswagen Transporter Van Sixth generation (2015-2021)

Transporter 2020 ➤  
Auxiliary heater - Edition 04.2020  
Fuel tank sufficiently filled (fuel gauge on dash panel insert not  
in red area).  
Check  
CAUTION  
The fuel system is pressurised.  
Risk of injury caused by fuel spray.  
– Wear safety goggles.  
– Wear protective gloves.  
– To release pressure, wrap a clean cloth around the connec‐  
tion, and carefully loosen the connection.  
– Unclip fuel line -2- from retainer -1-.  
– Unclip fuel line -2- from retainer -1-.  
– Remove clamp -3-.  
– Pull off fuel line -2-.  
– Guide fuel line -1- into measuring beaker - V.A.G 1602/1- .  
– Hold measuring beaker - V.A.G 1602/1- at same height as  
auxiliary heater.  
– Using ⇒ Vehicle diagnostic tester, check fuel delivery rate of  
metering pump - V54- .  
– Read quantity of diesel in measuring beaker - V.A.G 1602/1- .  
Min. quantity of fuel after 120 seconds, ml  
22  
Max. quantity of fuel after 120 seconds, ml  
28  
– If fuel delivery rates are not within specifications, renew me‐  
tering pump - V54- ⇒ page 29 .  
4.2  
Removing and installing metering pump  
- V54-  
Special tools and workshop equipment required  
♦ Engine bung set - VAS 6122-  
4. Fuel supply  
29  
Transporter 2020 ➤  
Auxiliary heater - Edition 04.2020  
♦ Drip tray for workshop hoist - VAS 6208-  
Removing  
– Remove left underbody cladding ⇒ General body repairs, ex‐  
terior; Rep. gr. 66 ; Underbody cladding; Assembly overview  
- underbody cladding .  
– Disconnect electrical connector -4-.  
– Loosen clamps -2-.  
CAUTION  
The fuel system is pressurised.  
Risk of injury caused by fuel spray.  
– Wear safety goggles.  
– Wear protective gloves.  
– To release pressure, wrap a clean cloth around the connec‐  
tion, and carefully loosen the connection.  
– Place drip tray - VAS 6208- beneath vehicle.  
– Pull off fuel hoses -3-.  
– Seal fuel hoses -3- with a bung from engine bung set - VAS  
6122- .  
– Remove metering pump - V54- -1- from bracket.  
Installing  
Install in reverse order of removal, observing the following:  
– Replace O-type clips with screw-type clips.  
30  
Rep. gr.82 - Supplementary heating