Audi 100 1991 ➤ , Audi 80 1992 ➤ , Audi A1 2011 ➤ , Audi A1 Sportback 2 ...
Air conditioner with refrigerant R134a - Edition 11.2018
Possible deviation from speci‐
Possible causes of fault
Fault elimination
fication
On vehicles without shut-off
valve upstream of evaporator
in air conditioning unit (e.g. -
N516- or -N541- , depending
on vehicle) ⇒ Heating, air con‐
ditioning; Rep. gr. 87 ; Refrig‐
erant circuit (vehicle-specific
Workshop Manual).
♦ Actuation of air conditioner compres‐ – Extract refrigerant from re‐
sor not OK ⇒ Vehicle diagnostic tester,
“Guided Fault Finding” function for air
conditioner, air conditioner compres‐
sor and battery regulation .
frigerant circuit.
•
If quantity of refrigerant ex‐
tracted is substantially less
than specified capacity:
♦ Not enough refrigerant in circuit
– Locate leak with leak detec‐
tor and repair it.
♦ Expansion valve for evaporator in air
conditioning unit defective.
•
•
High pressure normal
low pressure too low (below
specified value)
– Re-charge refrigerant circuit.
– Repeat test.
•
Required cooling output is
not attained at evaporator in
air conditioning unit.
•
If amount of refrigerant ex‐
tracted roughly corresponds
to specified capacity:
– Renew expansion valve for
evaporator in air conditioning
unit.
– Re-charge refrigerant circuit.
– Repeat test.
On a vehicle with a shut-off
valve upstream of the evapo‐
rator in the air conditioning unit
(e.g. -N516- or -N541- (de‐
pending on vehicle) ⇒ Heating,
air conditioning; Rep. gr. 87 ;
Refrigerant circuit (vehicle-
specific Workshop Manual).
♦ Actuation of air conditioner compres‐ – Extract refrigerant from re‐
sor not OK ⇒ Vehicle diagnostic tester,
“Guided Fault Finding” function for air
conditioner, air conditioner compres‐
sor and battery regulation .
frigerant circuit.
•
The quantity of refrigerant
extracted is much less than
the specified capacity (con‐
tinue in same way as a vehi‐
cle without a shut-off valve
upstream of the evaporator
in the air conditioning unit)
♦ Not enough refrigerant in circuit
♦ Expansion valve for evaporator in air
conditioning unit defective.
•
•
High pressure normal
low pressure too low (below
specified value)
♦ Shut-off valve upstream of the evapo‐
rator in the air conditioning unit (e.g. -
N516- or -N541- (depending on vehi‐
cle) defective (closed) ⇒ Heating, air
conditioning; Rep. gr. 87 ; Refrigerant
circuit (vehicle-specific Workshop
Manual).
•
If amount of refrigerant ex‐
tracted roughly corresponds
to specified capacity:
•
The required cooling output
is not attained at the evap‐
orator in the air conditioning
unit and at the evaporator
for cooling the high-voltage
components.
– Check activation and opera‐
tion of shut-off valve up‐
stream of evaporator in air
conditioning unit (e.g. -N516-
or -N541- ) and shut-off valve
upstream of evaporator for
cooling high-voltage compo‐
nents (e.g. -N517- or -
N542- , depending on vehi‐
cle) ⇒ Heating, air condition‐
ing; Rep. gr. 87 ; Refrigerant
circuit (vehicle-specific
Workshop Manual).
– Renew expansion valve up‐
stream of evaporator in air
conditioning unit.
– Replace expansion valve (or
restrictor) upstream of the
evaporator for cooling the
high-voltage components.
– Re-charge refrigerant circuit.
– Repeat test.
238
Rep. gr.87 - Air conditioning system