CHARGING CIRCUIT - ALTERNATOR WITH MONO-FUNCTION REGULATOR
ALL TYPES
CHECKING THE ALTERNATOR OUTPUT
Output under 13.5 V
Intensity (A) / Alternator speed
Connect as shown in the diagram opposite, using an ammeter (A), a
voltmeter (V), and a rheostat (R) or a Volt/Ammeter/Rheostat combination.
Adjust the engine speed (table opposite) and rheostat charge
according to the vehicle's equipment specification in order to obtain
U = 13.5 V.
Speed
2000
rpm
3000
rpm
4000
rpm
Class
5
29 A
42 A
49 A
62 A
72 A
99 A
43 A
59 A
39 A
54 A
62 A
76 A
90 A
128 A
Reminder : The excitation energising current will flow through the
warning lamp - check that the warning lamp comes on when the
ignition is switched on. It must go out when the engine has started
(accelerate slightly).
7
8
68 A
CHECKING THE VOLTAGE REGULATOR
9
83 A
the rheostat to zero and disconnect all the electrical consumers.
Display 5000 alternator rpm. If U alternator is > 14.7 V, the regulator is
faulty.Set
12
15
100 A
140 A
Note : These tests should be performed with the engine hot and the
battery fully charged.
D1AP01SC
299