6H-22 CHARGING SYSTEM
SPECIFICATIONS
BATTERY
Rated capacity
28 AH/5 HR, 12 Volts
Electrolyte 2.5 L (5.28/4.40 US/lmp pt)
Electrolyte S.G. 1.24 when fully charged at 20_C (68_F)
GENERATOR
NOTE:
The generator used in each vehicle is one of the following two types, depending on specification.
Type 40 A type 50 A type
Rated voltage 12 V
Nominal output 40 A (at 13.5 V) 50 A (at 13.5 V)
Permissible max. speed 18,000 rpm
No-load speed 1,110 r/min (rpm)
Setting voltage 14.2 to 14.8 V
Permissible ambient temperature –30 to 90 _C (–22 to 194 _F)
Polarity Negative ground
Rotation Clockwise viewed from pulley side