2008-2017 Vauxhall Insignia 4 Door Driving and operating -> Fuel User Manual
MyCarUserManual.com
USER MANUALS FOR EVERY MAKE & MODEL

Driving and operating -> Fuel for Your Vauxhall Insignia 4 Door First Generation (2008-2017)

Driving and operating  
205  
When the system recognises an  
unintended lane change, the control  
indicator ) changes to yellow and  
flashes. Simultaneously a chime  
sound is activated.  
The system cannot operate when no  
lane marking is detected.  
Fuel  
Fuel for petrol engines  
Only use unleaded fuel that complies  
with European standard EN 228 or  
E DIN 51626-1 or equivalent.  
Your engine is capable of running  
with E10 fuel that fulfills these  
standards. E10 fuel contains up to  
10 % bioethanol.  
Use fuel with the recommended  
octane rating 3 273. Use of fuel with  
too low an octane rating can reduce  
engine power and torque and slightly  
increases fuel consumption.  
Deactivation  
The system is deactivated by  
pressing ) button; the LED in the  
button extinguishes.  
At speeds below 56 km/h the system  
is inoperable.  
Caution  
Do not use fuel or fuel additives  
that contain metallic compounds  
such as manganese-based  
additives. This may cause engine  
damage.  
Fault  
The lane departure warning system  
may not operate properly when:  
■ the windscreen is not clean  
■ there are adverse environmental  
conditions, e.g. heavy rain, snow,  
direct sunlight or shadows  
206  
Driving and operating  
Caution  
The boiling point depends on the  
pressure and mixing ratio. At ambient  
pressure, it is between -42 °C (pure  
propane) and -0.5 °C (pure butane).  
Caution  
Use of fuel that does not comply to  
EN 228 or E DIN 51626-1 or  
equivalent can lead to deposits or  
engine damage and may affect  
your warranty.  
Use of fuel that does not comply to  
EN 590 or similar can lead to  
engine powerloss, increased wear  
or engine damage and may affect  
your warranty.  
Caution  
The system works at an ambient  
temperature of approx. -8 °C to  
100 °C.  
Do not use marine diesel oils, heating  
oils, Aquazole and similar diesel-  
water emulsions. Diesel fuels must  
not be diluted with fuels for petrol  
engines.  
Caution  
Full function of the LPG system can  
only be guaranteed with liquid gas  
which complies with the minimum  
requirements of DIN EN 589.  
Use of fuel with too low an octane  
rating could lead to uncontrolled  
combustion and engine damage.  
Fuel for liquid gas  
operation  
Fuel for diesel engines  
Fuel selector  
Only use diesel fuel that complies  
with EN 590.  
Liquid gas is known as LPG  
(Liquefied Petroleum Gas) or under  
its French name GPL (Gaz de Pétrole  
Liquéfié). LPG is also known as  
Autogas.  
In countries outside the European  
Union use Euro-Diesel fuel with a  
sulfur concentration below 50 ppm.  
LPG consists mainly of propane and  
butane. The octane rating is between  
105 and 115, depending on the  
butane proportion. LPG is stored  
liquid at around 5 - 10 bar pressure.  
Driving and operating  
Caution  
207  
Press the LPG button to switch  
between petrol and liquid gas  
operation as soon as the required  
parameters (coolant temperature,  
gas temperature and minimum  
engine speed) have been reached.  
The requirements are usually fulfilled  
after around 60 seconds (depending  
on exterior temperature) and the first  
firm press on the accelerator. The  
LED status shows the current  
operating mode.  
Fill the tank completely at regular  
intervals to prevent corrosion in the  
tank.  
Repairs and adjustments may only  
be made by trained specialists in  
order to maintain the safety and  
warranty on the LPG system.  
Faults and remedies  
If gas mode is not possible, check the  
following:  
■ Is there enough liquid gas present?  
■ Is there enough petrol present for  
starting?  
Due to extreme temperatures in  
combination with the gas  
composition, it may take slightly  
longer before the system switches  
from petrol to gas mode.  
In extreme situations, the system may  
also switch back to petrol mode if the  
minimum requirements are not  
fulfilled.  
Liquid gas is given a particular odour  
(odorised) so that any leaks can be  
detected easily.  
9 Warning  
1 off  
= petrol operation  
1 illumi‐  
nates  
= liquid gas operation  
If you smell gas in the vehicle or in  
the immediate vicinity, switch to  
petrol mode immediately. No  
smoking. No naked flames or  
ignition sources.  
1 flashes  
= no switching is  
possible, one type of  
fuel is empty  
As soon as the liquid gas tank is  
empty, petrol operation is  
automatically engaged until the  
ignition is switched off.  
If the gas odour persists, do not start  
the engine. If possible, close the  
manual shut-off valve on the  
multivalve. The multivalve is located  
on the liquid gas tank in the load  
compartment, underneath the rear  
floor cover.  
Seek the assistance of a workshop in  
the event of all other faults.  
Every six months, run the petrol tank  
down until control indicator i or Y  
illuminates, then refuel. This helps  
maintain fuel quality and system  
function for petrol operation.  
208  
Driving and operating  
Refuelling  
9 Danger  
Fuel is flammable and explosive.  
No smoking. No naked flames or  
sparks.  
If you can smell fuel in your  
vehicle, have the cause of this  
remedied immediately by a  
workshop.  
Caution  
Turn the thumb wheel clockwise.  
In case of misfuelling, do not  
switch on ignition.  
If no further gas odour is perceptible  
when the manual shut-off valve is  
closed, the vehicle can be used in  
petrol mode. If the gas odour persists,  
do not start the engine. Have the  
cause of the fault remedied by a  
workshop.  
When using underground car parks,  
follow the instructions of the operator  
and local laws.  
9 Danger  
Fuel filler flap is located at right rear  
side of vehicle.  
Before refuelling, switch off engine  
and any external heaters with  
combustion chambers. Switch off  
any mobile phones.  
Follow the operating and safety  
instructions of the filling station  
when refuelling.  
Note  
In the event of an accident, switch off  
the ignition and lights. Close the  
manual shut-off valve on multivalve.  
Driving and operating  
209  
Liquid gas refuelling  
Follow the operating and safety  
instructions of the filling station when  
refuelling.  
The filling valve for the liquid gas is  
behind the fuel filler cap.  
The fuel filler cap can be retained in  
the bracket on the fuel filler flap.  
To refuel, fully insert the pump nozzle  
and switch it on.  
After the automatic cut-off, the tank  
can be topped-up with a maximum  
two doses of fuel.  
The fuel filler flap can only be opened  
if the vehicle is unlocked. Release the  
fuel filler flap by pushing the flap.  
Petrol and Diesel refuelling  
To open, turn the cap slowly  
anticlockwise.  
Unscrew protective cap from the filler  
neck.  
Caution  
Wipe off any overflowing fuel  
immediately.  
To close, turn the fuel filler cap  
clockwise until it clicks.  
Close the flap and let engage.  
210  
Driving and operating  
ACME Adapter: Screw the nut of the  
filling nozzle onto the adapter. Press  
locking lever on filler nozzle down.  
DISH (Italy) filler neck: Place the filler  
nozzle into the adapter. Press locking  
lever on filler nozzle down.  
Bayonet filler neck: Place filler nozzle  
on the adapter and turn to the left or  
right through one quarter turn. Pull  
locking lever of filler nozzle fully.  
EURO filler neck: Press the filler  
nozzle onto the adapter until it  
engages.  
9 Warning  
Due to the system design, an  
escape of liquid gas after  
releasing the locking lever is  
unavoidable. Avoid inhaling.  
9 Warning  
The liquid gas tank may only be  
filled to 80% for safety reasons.  
Screw the required adapter hand-  
tight onto the filler neck.  
The multivalve on the liquid gas tank  
automatically limits the fill quantity. If  
a larger quantity is added, we  
recommend not exposing the vehicle  
to the sun until the excess amount  
has been used up.  
Press the button at the liquid gas  
supply point. The filling system stops  
or begins to run slowly when 80% of  
the tank volume is reached  
(maximum fill level).  
Release button on filling system and  
the filling process stops. Release the  
locking lever and remove the filler  
nozzle. A small quantity of liquid gas  
can escape.  
Filling adapter  
As filling systems are not  
standardised, different adapters are  
required which are available from  
Opel Distributors and from Opel  
Authorised Repairers.  
Remove adapter and stow in vehicle.  
Fit protective cap to prevent the  
penetration of foreign bodies into the  
filler opening and the system.  
Driving and operating  
211  
Croatia, Latvia, Lithuania,  
Macedonia, Austria, Poland,  
Portugal, Romania, Sweden,  
Switzerland, Serbia, Slovakia,  
Slovenia, Czech Republic, Turkey,  
Ukraine, Hungary  
Fuel filler cap  
Only use genuine fuel filler caps.  
Diesel-engined and Ethanol-engined  
vehicles have special fuel filler caps.  
Fuel consumption - CO2-  
Emissions  
ACME adapter: Belgium, Germany,  
Ireland, Luxembourg, Switzerland  
EURO adapter: Spain  
The fuel consumption (combined) of  
the model Opel Insignia is within a  
range of 11.0 to 3.7 l/100 km.  
The CO2 emission (combined) is  
within a range of 259 to 98 g/km.  
For the values specific for your  
vehicle, refer to the EEC Certificate of  
Conformity provided with your vehicle  
or other national registration  
documents.  
DISH (Italy) adapter: Bosnia-  
Herzegovina, Bulgaria, Denmark,  
Estonia, France, Greece, Italy,  
Bayonet adapter: Netherlands,  
Norway, Spain, United Kingdom  

Related Topics

Popular Owner Manuals