Amarok 2011 ➤, Amarok 2017 ➤
Electrical system - Edition 12.2020
Note
Additional information:
⇒ Current flow diagrams, Electrical fault finding and Fitting loca‐
tions
⇒ Body builder guidelines Amarok
base.com/amarok-aufbaurichtlinien)
General description:
Using the electric interface for external use (UF1), body builders
can access selected parts of the onboard supply system in or‐
der to connect special equipment to the onboard supply system.
Before using the electric interface for external use, always ob‐
serve the comprehensive set of regulations and information
in the ⇒ Body builder guidelines Amarok
base.com/amarok-aufbaurichtlinien).
The connectors of the electric interface for external use -1- are
located on the wiring harness behind the fuse box. They can be
accessed via the driver footwell.
1.4.2
Connector pin assignment - electric in‐
terface for external use
Note
Note the additional information on the pin assignment: ⇒ Body
builder guidelines Amarok
ok-aufbaurichtlinien).
Pin assignment connector 1 (blue)
P P Col‐ Application
i ot our
n e
nt
ia
l
A 7 Blac Terminal 75A (electronic ignition lock)
1 5 k/
A white
A 5 Grey Fog lights
2 5 /
yel‐
low
1. Relay carriers, fuse holders, electronics boxes