Polo 2018 ➤, Polo 2022 ➤, Taigo 2022 ➤
Maintenance - Edition 10.2021
♦ Vehicle identification number “field E”
♦ Type and version “Field D2 (type only)”, “Field 2.2 (code for
field D.2)”
♦ Nominal speed “field P4”
Specified data input for EET
There are different ways to enter the specified data:
♦ 1. By manual input
♦ 2. By automatic data acceptance from the exhaust-emission
station database
Note
♦ Regarding Euro 6 vehicles with manual gearbox and info‐
tainment system, the deactivation of the idle speed limitation
is carried out in the infotainment system. ⇒ page 189
♦ Euro 6 vehicles with automatic gearbox, manufactured from
week no. 48/18 do not have idle speed limitation any more.
♦ If there is no ESP or soft key in the infotainment system
to deactivate the speed limitation, the governed speed can
be measured using the engine speed limited by the control
unit. To do this, all the EET specifications must be entered
manually.
-1
♦
For all Euro 6 vehicles an opacity figure of max. 0.25 m
applies.
Deactivation of idle speed limitation of Euro 6 vehicles with
manual gearbox:
– Switch on ignition.
– Switch on Infotainment system.
– Press Home function button.
– Press Vehicle function button.
– Press Setup function button.
– Press ESC system function button and deactivate TCS.
Manual specified data input for EET:
Note
♦ For the relevant test requirements and all the necessary da‐
ta for the exhaust emissions test, refer to the ⇒ Data sheets
for exhaust emissions test of the respective engine.
♦ The nominal speed is located in field P4 of the registration
certificate part 1 or field 7 of the vehicle document and must
always be entered manually.
♦ If the idle speed limitation cannot be deactivated, enter the
value 2500 ± 200 rpm in the box for rev limit and 2500 in the
box for engine speed for conditioning.
– Perform manual data input according to instructions on dis‐
play.
– Enter displayed values on EET data sheet in column “Test
values for exhaust emissions test” on display as follows:
5. Exhaust emissions test
189