Regulation of auxiliary air heater -> 9.2 Function of auxiliary air heater operating and display unit E407 or roof display unit J702 for Your Volkswagen Transporter Van Sixth generation (2015-2021)

Transporter 2020 ➤  
Auxiliary heater - Edition 04.2020  
will continue for about 4 minutes. The control unit is locked out  
after the permitted number of unsuccessful start attempts has  
been exceeded.  
♦ If the flame goes out by itself during heating operation, a new  
start is performed initially. If the heating unit does not ignite  
within 90 seconds after fuel delivery restarts or if it ignites but  
goes out within 15 minutes, a malfunction shut-off occurs. That  
means that fuel delivery will be ended and blower run-on will  
continue for about 4 minutes.  
Note  
The malfunction shut-down can be revoked by briefly switch‐  
ing off and back on again.  
Do not repeat the switch on/off procedure more than twice.  
♦ Overheating causes the combination sensor (flame monitor/  
overheating sensor) to be tripped, the fuel supply is interrupted  
and a malfunction shut-down is performed. Once the cause of  
overheating has been eliminated, the heater unit can be re‐  
started by switching off and back on again. The control unit is  
locked out after the permitted number of unsuccessful start  
attempts has been exceeded.  
♦ A malfunction shut-down will occur 20 seconds after the lower  
or upper voltage limit has been reached.  
♦ The heater unit will not start if the glow plug or the blower motor  
is defective, or if there is a discontinuity in the electrical cable  
to the metering pump.  
♦ If the combination sensor (flame monitor/overheating sensor)  
is defective or there is a discontinuity in the electrical cable,  
the heater unit starts and the malfunction shut-down occurs  
only during the start phase.  
♦ The speed of the blower motor is continuously monitored. A  
malfunction shut-down will occur after 30 seconds if the blower  
motor does not start or if the speed fluctuates by more than  
10%.  
♦ When the heater unit is switched off, the glow plug is switched  
on for 40 seconds during blower run-on (post-glow) to burn off  
combustion residues.  
Switching off in an emergency  
If an emergency shut-off (emergency off) is required during op‐  
eration, proceed as follows:  
Switch off heater unit via control element, or  
Pull out fuse, or  
Isolate heater unit from battery.  