Air conditioning system with refrigerant R134a - Edition 10.2014
•
Do not throw pressure vessels!
When falling, the containers may become severely deformed so
that they may be torn open. The refrigerant evaporates immedi‐
ately, releasing violent forces. Flying fragments of cylinders can
cause severe injuries.
Bottle valves can brake during improper transport. To protect cyl‐
inder valves, bottles may be transported only with protective
covers screwed on.
•
Do not place near radiators!
High temperatures can occur near radiators. Higher temperatures
however also mean higher pressures, which may exceed the rat‐
ed pressure of the vessel.
1.10.12 Do not heat above 50°C
To prevent danger, the Regulations for Pressure Tanks provide
that tanks shall not be heated to more than 50°C.
1.10.13 Do not apply uncontrolled heat
Do not heat with an open flame under any circumstance. The local
overheating that will result can change the structure of the con‐
tainer's materials, thereby reducing the safe maximum pressure
limit of the container. In addition, the danger arises that the re‐
frigerant decomposes due to localised overheating.
1.10.14 Seal empty containers
Empty refrigerant containers must in all cases be sealed so as to
prevent intrusion of moisture. Moisture causes steel containers to
rust. This weakens the walls of the containers. In addition, rust
particles which enter the refrigerant system from the container
cause malfunctions.
1.10.15 Safety instructions for using extraction
and charging equipment
•
Before connecting the charging system to the air conditioning
system, make sure that all existing shut-off valves are closed.
•
Before the charging equipment is decoupled from the air con‐
ditioning system, ensure that the process has finished. The
reason for this is to ensure that no refrigerant oil escapes into
the atmosphere.
•
After the cleaned refrigerant from the charging system has
been charged into an external pressurised gas cylinder, close
the hand shut-off valves on the bottle and the charging system.
•
•
•
Do not expose charging system to moisture or use it in a wet
environment.
Before performing service work and the charging system, dis‐
connect the current supply.
To reduce danger of fire, avoid using extension cords. If nev‐
ertheless it is necessary to use an extension cable, use an
2
extension cable with a cross-section of at least 2.5 mm .
•
•
In case of fire, remove external cylinder.
If entrained oil from the air conditioning system suction accu‐
mulator is trapped in the measuring beaker supplied, be sure
subsequently to pour the oil into a container that can be
sealed, since the oil contains a small amount of refrigerant.
Refrigerants must not be released into the environment.
•
When the air conditioner service station is switched off, it must
be secured against rolling away.