COOLING SYSTEM SPECIFICATIONS
Engines: ES9A - DTE17BTED4
3.0i 24S
XFV
2,7 24V
UHZ
Engine type
11,3
13,2
Capacity
Radiator surface
Pressurisation
Opening of thermostatic regulator
Cooling fan
27 dm2
1,4 bar
78°C
1 x 600 W
FRIC function
105°C
83°C
2 x 150W
1st speed
97°C or aircon in operation
101°C or 17 bars in the aircon circuit
105° or 30 bars in the aircon circuit
115°C or 30 bars in the aircon circuit
2nd speed
3rd speed
Air con cut-off
Alert
118°C
Post cooling
6 minutes
Marking
11
6
Information
Level of coolant
Resistance
Black
Temperature of coolant
Thermostat
Temperature, diesel injection, alert, aircon
Sensor
Thermostat
Grey
Colour of connector
Tightening (m.daN)
Blue
1,7 0,4
73