AC–17
AIR CONDITIONING
–
AIR INLET SERVOMOTOR
AC39K–01
”REC”
”FRS”
”REC”
”FRS”
INSPECTION
1.
LHD:
INSPECT AIR INLET SERVOMOTOR OPERATION
7
1
(a) Connect the positive (+) lead from the battery to terminal
7 and negative (–) lead to terminal 1 and check that arm
turns to ”REC” side smoothly.
If operation is not as specified, replace the servomotor.
I19376
I19377
I18814
I18815
(b) Connect the positive (+) lead from the battery to terminal
7 and the negative (–) lead to terminal 3 and check that
the arm turns to ”FRS” side smoothly.
7
3
If operation is not as specified, replace the servomotor.
2.
RHD:
INSPECT AIR INLET SERVOMOTOR OPERATION
7
1
(a) Connect the positive (+) lead from the battery to terminal
7 and negative (–) lead to terminal 1 and check that arm
turns to ”REC” side smoothly.
If operation is not as specified, replace the servomotor.
(b) Connect the positive (+) lead from the battery to terminal
7 and the negative (–) lead to terminal 3 and check that
the arm turns to ”FRS” side smoothly.
7
3
If operation is not as specified, replace the servomotor.
AVENSIS/CORONA SUP (RM781E)