AIR CONDITIONING -> Air Outlet Servomotor for Your Toyota Avensis 4 Door First Generation (1997-2003)

AC–23  
AIR CONDITIONING  
AIR OUTLET SERVOMOTOR  
AIR OUTLET SERVOMOTOR  
AC39P–01  
REMOVAL  
REMOVE AIR OUTLET SERVOMOTOR  
(a) Disconnect the connector.  
(b) Remove the 3 screws and air outlet servomotor.  
I19341  
AVENSIS/CORONA SUP (RM781E)  
AC–24  
AIR CONDITIONING  
AIR OUTLET SERVOMOTOR  
AC39Q–01  
”DEF”  
INSPECTION  
5
4
1.  
LHD:  
INSPECT AIR OUTLET SERVOMOTOR OPERATION  
(a) Connect the positive (+) lead from the battery to terminal  
4 and negative (–) lead to terminal 5 and check that arm  
turns to ”DEF” side smoothly.  
If operation is not as specified, replace the servomotor.  
I19334  
(b) Connect the positive (+) lead from the battery to terminal  
5 and the negative (–) lead to terminal 4 and check that  
the arm turns to ”FACE” side smoothly.  
”FACE”  
5
4
If operation is not as specified, replace the servomotor.  
I19335  
2.  
LHD:  
”DEF”  
INSPECT AIR OUTLET POSITION SENSOR RESIS-  
TANCE  
5 4 3  
2
Measure resistance between terminals at servomotor arm each  
position as shown in the chart.  
Testerconnection  
Condition  
Constant  
Specifiedcondition  
4.2 – 7.8 k  
2 – 1  
3 – 2  
3 – 2  
Arm position at ”DEF”  
Arm position at ”FACE”  
3.49 – 6.47 kΩ  
0.71 – 1.33 kΩ  
If resistance is not as specified, replace the servomotor.  
”FACE”  
5 4 3  
2
I19338  
AVENSIS/CORONA SUP (RM781E)  
AC–25  
AIR CONDITIONING  
AIR OUTLET SERVOMOTOR  
3.  
RHD:  
INSPECT AIR OUTLET SERVOMOTOR OPERATION  
”DEF”  
5
4
(a) Connect the positive (+) lead from the battery to terminal  
5 and negative (–) lead to terminal 4 and check that arm  
turns to ”DEF” side smoothly.  
If operation is not as specified, replace the servomotor.  
I19336  
(b) Connect the positive (+) lead from the battery to terminal  
4 and the negative (–) lead to terminal 5 and check that  
the arm turns to ”FACE” side smoothly.  
”FACE”  
5
4
If operation is not as specified, replace the servomotor.  
I19337  
4.  
RHD:  
INSPECT AIR OUTLET POSITION SENSOR RESIS-  
TANCE  
”FACE”  
5 4 3 1  
Measure resistance between terminals at servomotor arm each  
position as shown in the chart.  
Testerconnection  
Condition  
Constant  
Specifiedcondition  
4.2 – 7.8 kΩ  
2 – 1  
3 – 1  
3 – 1  
Arm position at ”DEF”  
Arm position at ”FACE”  
3.49 – 6.47 kΩ  
0.71 – 1.33 kΩ  
If resistance is not as specified, replace the servomotor.  
5 4 3 1  
”DEF”  
I19339  
AVENSIS/CORONA SUP (RM781E)  
AC–26  
AIR CONDITIONING  
AIR OUTLET SERVOMOTOR  
AC39R–01  
INSTALLATION  
Installation is in the reverse order of removal (See page AC–23).  
AVENSIS/CORONA SUP (RM781E)