AIR CONDITIONING -> Air Mix Servomotor for Your Toyota Avensis 4 Door First Generation (1997-2003)

AC–19  
AIR CONDITIONING  
AIR MIX SERVOMOTOR  
AIR MIX SERVOMOTOR  
AC39M–01  
REMOVAL  
1.  
REMOVE BLOWER UNIT (See page AC–16)  
2.  
REMOVE AIR MIX SERVOMOTOR  
(a) Disconnect the connector.  
(b) Remove the 3 screws and air mix servomotor.  
I19340  
AVENSIS/CORONA SUP (RM781E)  
AC–20  
AIR CONDITIONING  
AIR MIX SERVOMOTOR  
AC39N–01  
INSPECTION  
1.  
LHD:  
7
6
INSPECT AIR MIX SERVOMOTOR OPERATION  
(a) Connect the positive (+) lead from the battery to terminal  
6 and the negative (–) lead to terminal 7 and check that  
the arm turns to ”WARM” side smoothly.  
”WARM”  
”COOL”  
If operation is not as specified, replace the servomotor.  
I18817  
(b) Connect the positive (+) lead from the battery to terminal  
7 and negative (–) lead to terminal 6 and check that arm  
turns to ”COOL” side smoothly.  
7
6
If operation is not as specified, replace the servomotor.  
I18816  
2.  
LHD:  
INSPECT AIR MIX POSITION SENSOR RESISTANCE  
Measure resistance between terminals at servomotor arm each  
position as shown in the chart.  
7 6  
5
1
Testerconnection  
Condition  
Constant  
Specifiedcondition  
4.2 – 7.8 k  
3 – 1  
5 – 1  
5 – 1  
Arm position at ”WARM”  
Arm position at ”COOL”  
0.84 – 1.56 kΩ  
3.36 – 6.24 kΩ  
”WARM”  
”COOL”  
If resistance is not as specified, replace the servomotor.  
7 6  
5
1
I19332  
AVENSIS/CORONA SUP (RM781E)  
AC–21  
AIR CONDITIONING  
AIR MIX SERVOMOTOR  
3.  
RHD:  
INSPECT AIR MIX SERVOMOTOR OPERATION  
7
6
(a) Connect the positive (+) lead from the battery to terminal  
6 and the negative (–) lead to terminal 7 and check that  
the arm turns to ”COOL” side smoothly.  
If operation is not as specified, replace the servomotor.  
”COOL”  
”WARM”  
I18817  
(b) Connect the positive (+) lead from the battery to terminal  
7 and negative (–) lead to terminal 6 and check that arm  
turns to ”WARM” side smoothly.  
7
6
If operation is not as specified, replace the servomotor.  
I18816  
4.  
RHD:  
INSPECT AIR MIX POSITION SENSOR RESISTANCE  
Measure resistance between terminals at servomotor arm each  
position as shown in the chart.  
7 6  
5
3
Testerconnection  
Condition  
Constant  
Specifiedcondition  
4.2 – 7.8 kΩ  
3 – 1  
5 – 3  
5 – 3  
Arm position at ”COOL”  
Arm position at ”WARM”  
3.36 – 6.24 kΩ  
0.84 – 1.56 kΩ  
”COOL”  
”WARM”  
If resistance is not as specified, replace the servomotor.  
7 6  
5
3
I19333  
AVENSIS/CORONA SUP (RM781E)  
AC–22  
AIR CONDITIONING  
AIR MIX SERVOMOTOR  
AC39O–01  
INSTALLATION  
Installation is in the reverse order of removal (See page AC–19).  
AVENSIS/CORONA SUP (RM781E)