AX–7
AUTOMATIC TRANSAXLE (U240E)
–
NEUTRAL START SWITCH
(e) Remove the 2 bolts and pull out the neutral start switch.
4. INSTALL AND ADJUST NEUTRAL START SWITCH
(a) Install the neutral start switch with the 2 bolts.
Torque: 5.4 N·m (55 kgf·cm, 48 in.·lbf)
(b) Install a new lock plate and nut.
Torque: 6.9 N·m (70 kgf·cm, 61 in.·lbf)
(c) Bend the claws on the lock plate to fix the nut.
D05915
D05913
D05912
D05911
(d) Install the control shift lever with the nut.
Torque: 13 N·m (130 kgf·cm, 9 ft·lbf)
(e) Connect the control cable to the control shaft.
Torque: 12 N·m (120 kgf·cm, 9 ft·lbf)
5.
CONNECT NEUTRAL START SWITCH CONNECTOR
6.
CHECK NEUTRAL START OPERATION
Check that the engine can be started with the shift lever only in
the N or P range, but not in other position.
If the engine can not be stated not as started above, carry out
the adjustment procedure (See page DI–62).
7.
8.
INSTALL AIR CLEANER ASSEMBLY
TEST DRIVE VEHICLE
AVENSIS/CORONA SUP (RM781E)