AX–14
AUTOMATIC TRANSAXLE (U240E)
–
SHIFTLOCK SYSTEM
AX10Z–01
INSPECTION
5 (IG)
1 (ACC)
1.
LHD:
4 (KLS+)
INSPECT SHIFT LOCK CONTROL COMPUTER
Using a voltmeter, measure the voltage at each terminal.
HINT:
3 (E)
Do not disconnect the shift lock control computer connector.
2 (STP)
Wire harness side
D00758
Terminal
MeasuringCondition
Voltage (V)
10 – 14
1 – 3 (ACC – E)
5 – 3 (IG – E)
Ignition switch ACC
Ignition switch ON
10 – 14
2 – 3 (STP – E)
Depressing brake pedal
10 – 14
(1) Ignition switch ACC and P range
0
+
4 – 3 (KLS – E)
(2) Ignition switch ACC and except P range
7.5 – 11
6 – 9.5
(3) Ignition switch ACC and except P range (After approx. 1 second)
2.
RHD:
INSPECT SHIFT LOCK CONTROL COMPUTER
Using a voltmeter, measure the voltage at each terminal.
HINT:
Do not disconnect the shift control computer connector.
D05910
Terminal
MeasuringCondition
Voltage (V)
10 – 14
2 – 3 (ACC – E)
4 – 3 (IG – E)
5 – 3 (STP – E)
Ignition switch ACC
Ignition switch ON
10 – 14
Depressing brake pedal
10 – 14
(1) Ignition switch ACC and P range
0
+
1 – 3 (KLS – E)
(2) Ignition switch ACC and except P range
7.5 – 11
6 – 9.5
(3) Ignition switch ACC and except P range (After approx. 1 second)
AVENSIS/CORONA SUP (RM781E)