SS–25
SERVICE SPECIFICATIONS
–
AUTOMATIC TRANSAXLE(U240E)
RHD
Shift schedule (NORM mode)
D range
(Throttle valve fully opened)
1 → 2 53 – 60 km/h (33 – 37 mph)
2 → 3 99 – 107 km/h (62 – 66 mph)
3 → 4 154 – 166 km/h (96 – 103 mph)
4 → 3 146 – 159 km/h (91 – 99 mph)
3 → 2 92 – 99 km/h (57 – 62 mph)
2 → 1 46 – 52 km/h (29 – 32 mph)
3 → 4 35 – 41 km/h (22 – 25 mph)
4 → 3 16 – 21 km/h (10 – 13 mph)
(Throttle valve fully closed)
2 range
(Throttle valve fully opened)
1 → 2 53 – 60 km/h (33 – 37 mph)
3 → 2 99 – 10 km/h (62 – 66 mph)
L range
(Throttle valve fully opened)
3 → 2 99 – 107 km/h (62 – 66 mph)
2 → 1 48 – 54 km/h (30 – 34 mph)
Shift schedule (PWR mode)
D range
(Throttle valve fully opened)
1 → 2 53 – 60 km/h (33 – 37 mph)
2 → 3 99 – 107 km/h (62 – 66 mph)
3 → 4 154 – 166 km/h (96 – 103 mph)
4 → 3 146 – 159 km/h (91 – 99 mph)
3 → 2 92 – 99 km/h (57 – 62 mph)
2 → 1 46 – 52 km/h (29 – 32 mph)
3 → 4 35 – 41 km/h (22 – 25 mph)
4 → 3 17 – 23 km/h (11 – 14 mph)
(Throttle valve fully closed)
2 range
(Throttle valve fully opened)
1 → 2 53 – 60 km/h (33 – 37 mph)
3 → 2 99 – 107 km/h (62 – 66 mph)
L range
(Throttle valve fully opened)
3 → 2 99 – 107 km/h (62 – 66 mph)
2 → 1 48 – 54 km/h (30 – 34 mph)
Shift schedule (SNOW mode)
D range
(Throttle valve fully opened)
2 → 3 99 – 107 km/h (62 – 66 mph)
3 → 4 154 – 166 km/h (96 – 103 mph)
4 → 3 146 – 159 km/h (91 – 99 mph)
3 → 2 92 – 99 km/h (57 – 62 mph)
3 → 4 35 – 41 km/h (22 – 25 mph)
4 → 3 16 – 21 km/h (10 – 13 mph)
(Throttle valve fully closed)
Lock–up point (NORM mode)
O/D gear
(Throttle valve opening 5%)
Lock–up ON 58 – 64 km/h (36 – 40 mph)
Lock–up OFF 54 – 60 km/h (34 – 37 mph)
Lock–up point (PWR mode)
O/D gear
(Throttle valve opening 5%)
Lock–up ON 64 – 71 km/h (40 – 44 mph)
Lock–up OFF 61 – 67 km/h (38 – 42 mph)
AVENSIS/CORONA SUP (RM781E)