Electrical Equipment General Information - Edition 08.2019
Early Release
– Push the operating lever -1- upward in the direction of the
-arrow A-.
– At the same time push the crimping pliers together and then
open.
Caution
♦ Do not use the crimp connector after it is early released.
2.5
Fiber-Optic Cables, Repairing
⇒ “2.5.1 Determine Position of the Error”, page 136
⇒ “2.5.2 Fiber-Optic Cable, Preparing with the Fiber-Optic Con‐
ductor Repair Set VAS6223A ”, page 137
⇒ “2.5.3 Fiber-Optic Cable, Preparing with the Fiber-Optic Con‐
ductor Repair Set VAS6223A ”, page 141
⇒ “2.5.4 Fiber-Optic Cable, Disconnecting from Wiring Harness
Connector”, page 145
2.5.1
Determine Position of the Error
Special tools and workshop equipment required
♦ VehiPcrloetecDteidabgyncoopsyrtiigcht.TCeopsytiengrfor private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Caution
Do not bend the fiber-optic cable too much. The bending radius
must be no less than 25 mm.
Fiber optic cables must not be routed over sharp edges.
The fiber-optic cable must not be dirty or touched with bare
fingers.
Fiber optic cables may not be heated.
It is not permitted to twist together 2 fiber optic cables or one
fiber optic cable with a copper wire.
Protect the connector and the connection box from dust. Place
the cap on the trunk.
Procedure
It is very difficult to find the exact location of the problem. Replace
the damaged fiber-optic cable and lay a new wire parallel to the
defective fiber-optic cable.
Note
♦ Via the “Guided Fault Finding” it can be determines which
component of the fiber-optic cable is damaged.
♦ A fiber-optic cable that needs repair is represented by a “yel‐
low” color.
– Perform in the “Off-board Diagnostic Information System Serv‐
ice” the “Ring break diagnosis” function in the Vehicle Diag‐
nostic Tester .
136
Rep. Gr.97 - Wires