Touareg 2003 ➤
8-cylinder injection engine - Edition 11.2011
– Connect contact -1- of water pump -V36- to battery positive
lk
(+) and contact -2- to earth (-) using auxiliary cables from aux‐
iliary measuring set -V.A.G 1594C- . Pump must run.
If the pump does not start operating:
– Renew water pump -V36- .
1.9
Draining and filling coolant
Special tools and workshop
equipment required
♦ Refractometer -T10007-
♦ Drip tray -V.A.G 1306-
♦ Spring-type clip pliers -VAS
5024A-
♦ Adapter for cooling system
tester -V.A.G 1274/8-
♦ Torque wrench -V.A.G
1331-
♦ Cooling system charge unit
-VAS 6096-
86
Rep. gr.19 - Cooling