FOX 2004 ➤
3 - Cyl. injection engine - Edition 12.2009
♦ Check the firm seating of the fuel hoses.
♦ Do not invert supply and return hoses (return hose blue or with
blue marking, supply hose black).
Note
♦ Once the fuel reservoir is installed, check if supply, return and
ventilation hose sets are still fixed.
♦ If fuel tank has been replaced, it is necessary to drain the air
from the fuel system ⇒ page 68 .
1.7
Fuel shut off in case of accident
1.7.1
Operation
The fuel is shut off in case of an accident in order to reduce risk
of fire in the vehicle after a collision, in which the Fuel pump (pre-
supply pump) -G6- is disconnected by the Fuel pump relay -J17- .
At the same time, with this equipment, the engine starts more
smoothly.
When opening the fuel system, consider the following safety pre‐
cautions ⇒ page 65 .
lk
– Check the Fuel pump relay -J17- : ⇒ Current flow diagrams,
Electrical fault finding and Fitting locations
70
Rep. Gr.20 - Supply system - tank, Fuel pump (pre-supply pump) G6