3 - Cyl. injection engine - Edition 12.2009  
lk  
2
Activated charcoal filter system  
Operation ⇒ page 80 .  
Activated charcoal filter system components - repair  
⇒ page 81 .  
Check fuel compartment ventilation ⇒ page 81 .  
2.1  
Operation  
Fuel vapours form over the fuel surface on the tank, depending  
on the atmospheric pressure and ambient temperature.  
The activated charcoal filter prevents these hydrocarbon emis‐  
sions from being released into the atmosphere.  
The fuel vapours coming from the highest point of the tank go  
through the gravity valve (which closes at a 45° inclination) and  
check valve, strangled in its amount, to the activated charcoal  
filter.  
The activated charcoal absorbs these vapours like a sponge.  
While driving and with Lambda adjustment active (hot engine),  
the electromagnetic valve 1 for activated charcoal filter system -  
N80- , (also known as regeneration valve) is activated cyclically  
by the Engine control unit -J623- , due to engine speed and load.  
The opening period depends on the input signals.  
Intake manifold vacuum aspirates fresh air through the vent open‐  
ing on the lower part of the activated charcoal filter, during the  
activated charcoal regeneration process. The fuel vapours stored  
in the activated charcoal and the fresh air are fed for combustion  
in dosed quantities.  
The pressure retention valve prevents the fuel vapours from being  
aspirated into the fuel reservoir, when the Magnetic valve I for  
activated charcoal filter -N80- is opened and there is vacuum in  
the intake manifold. This way, the activated charcoal filter regen‐  
eration is ensured.  
With no current (e.g., driver interruption) the Magnetic valve 1 for  
activated charcoal filter -N80- remains closed. The activated char‐  
coal filter will not be purged.  
Note  
The flexible tube joints are fixed with a quick coupling.  
Always replace fastening clamps with spring clamps.  
To install spring clamps, we recommend using the Standart-  
type clamp pliers -VW 5162 - or Standart-type clamp pliers -  
VAS 5024A- .  
Follow safety measures ⇒ page 65 .  
Follow cleaning rules ⇒ page 65 .  
80  