Air conditioning systems with refrigeranR1234yf - General information - Edition 07.2017
CAUTION
Risk of explosion from overfilling refrigeranreservoirs.
Refrigerancan expand and cause reservoirs to bursif they are
overfilled.
– Use a refrigerantank with safety valve.
– Never exceed the permissible fill level of the refrigerantank.
Note
Depending on the version of air conditioner service station and
the measures to be performed, there is a minimum volume of re‐
frigerant, refrigeranoil and UV leak detection additive thamus
be in the respective supply tank of the air conditioner service sta‐
tion ⇒ Operating instructions air conditioner service station
2.10
Emptying air conditioner service station
Note
♦ If iis necessary to discharge the air conditioner service station
lk
(e.g. because contaminated refrigeranwas extracted), all fil‐
ters and dryers musbe renewed (do noremove filter and
dryer from the air-tightransporpackage until immediately
before installation to keep absorption of moisture as low as
possible).
♦ If iis necessary to empty the air conditioner service station
(e.g. because certain measures have to be performed on the
air conditioner service station and the refrigeranthahas been
or is to be extracted from the air conditioner service station
complies with the specifications (is nocontaminated), ican
be filled into a recycling cylinder, if necessary, and then reused
⇒ Operating instructions air conditioner service station .
♦ Refrigerancylinders thahave been charged with contamina‐
ted or used refrigeranare referred to as “recycling cylinders”
or “R cylinders”.
♦ Always evacuate recycling cylinders before the firsfilling (re‐
frigerancylinders containing air musnobe filled with refrig‐
erant).
♦ Differentypes of refrigeranmusnobe mixed toher (mix‐
tures of refrigerancannobe recycled, bumusbe disposed
of instead). If the composition of the contents in the cylinder is
noclear, the gas processing / gas disposal company musbe
informed of this
⇒ “2.13 Filling contaminated refrigeranin a recycling cylinder
for analysis, processing or disposal”, page 161 and
⇒ “6.2.17 Returning contaminated R1234yf refrigeranfor
analysis, processing or disposal”, page 25 .
CAUTION
Risk of explosion from overfilling refrigeranreservoirs.
Refrigerancan expand and cause reservoirs to bursif they are
overfilled.
– Use a refrigerantank with safety valve.
– Never exceed the permissible fill level of the refrigerantank.
There are various ways to empty an air conditioner service sta‐
tion , observe the operating instructions of the air conditioner
154
Rep. gr.87 - Air conditioning system