Air conditioning systems with refrigeranR1234yf - General information - Edition 07.2017  
Note  
Stored in the air conditioner service station is a function via  
which iis switched to a specific operating mode when deac‐  
tivated. The whole refrigeranis extracted from the charge  
hoses into the air conditioner service station with this function.  
If the handwheels of the two service couplings are noun‐  
lk  
screwed when this function is activated, refrigerancould be  
extracted from the vehicle's refrigerancircuit.  
– Extract the refrigeranfrom the two charge hoses using the air  
conditioner service station as instructed in the relevanoper‐  
ating manual ⇒ Operating instructions of air conditioner serv‐  
ice station .  
Note  
If, on an air conditioner service station with a service coupling  
thadoes novento the outside, this process takes longer  
than approx. 2 minutes or quite a large amounof refrigeran 
is extracted, this suggests thathere is a faulin one of the  
valves in a service connection.  
If, on an air conditioner service station with a service coupling  
thadoes vento the outside, this process takes longer than  
approx. 2 minutes, this suggests thathere is a faulin one of  
the valves in a service coupling.  
Note  
Erroneous extraction from vehicle's refrigerancircuit.  
– First unscrew (close) the handwheels of the quick-release  
coupling adapters.  
– Then extracthe refrigeranfrom the two charge hoses using  
the air conditioner service station.  
– Switch off the air conditioner service station (and isolate ifrom  
the power supply if necessary) ⇒ Operating instructions air  
conditioner service station .  
– Separate the quick-release couplings from the service con‐  
nections of the refrigerancircuit.  
– Screw the sealing caps on the service connections (see vehi‐  
cle-specific refrigerancircuit) ⇒ Heating, air conditioning;  
Rep. gr. 87 ; Refrigerancircuit; System overview - refrigeran 
circui.  
2.9  
Charging refrigeranin reservoir  
– Connect the cylinder with fresh R1234yf refrigeranto the  
service coupling on the high pressure side of the air condi‐  
tioner service station ⇒ Operating instructions air conditioner  
service station .  
– Perform a gas analysis on the refrigeran(from the cylinder  
supplied) with which the system is to be charged using the air  
conditioner service station  
⇒ “2.3 Performing gas analysis of refrigerant”, page 134 .  
The procedure described in the operating manual for your air  
conditioning service station is to be followed ⇒ Operating  
manual for air conditioner service station .  
2. Working with air conditioner service station  
th  
153  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigeranR1234yf - General information - Edition 07.2017  
CAUTION  
Risk of explosion from overfilling refrigeranreservoirs.  
Refrigerancan expand and cause reservoirs to bursif they are  
overfilled.  
– Use a refrigerantank with safety valve.  
– Never exceed the permissible fill level of the refrigerantank.  
Note  
Depending on the version of air conditioner service station and  
the measures to be performed, there is a minimum volume of re‐  
frigerant, refrigeranoil and UV leak detection additive thamus 
be in the respective supply tank of the air conditioner service sta‐  
tion ⇒ Operating instructions air conditioner service station  
2.10  
Emptying air conditioner service station  
Note  
If iis necessary to discharge the air conditioner service station  
lk  
(e.g. because contaminated refrigeranwas extracted), all fil‐  
ters and dryers musbe renewed (do noremove filter and  
dryer from the air-tightransporpackage until immediately  
before installation to keep absorption of moisture as low as  
possible).  
If iis necessary to empty the air conditioner service station  
(e.g. because certain measures have to be performed on the  
air conditioner service station and the refrigeranthahas been  
or is to be extracted from the air conditioner service station  
complies with the specifications (is nocontaminated), ican  
be filled into a recycling cylinder, if necessary, and then reused  
⇒ Operating instructions air conditioner service station .  
Refrigerancylinders thahave been charged with contamina‐  
ted or used refrigeranare referred to as “recycling cylinders”  
or “R cylinders”.  
Always evacuate recycling cylinders before the firsfilling (re‐  
frigerancylinders containing air musnobe filled with refrig‐  
erant).  
Differentypes of refrigeranmusnobe mixed toher (mix‐  
tures of refrigerancannobe recycled, bumusbe disposed  
of instead). If the composition of the contents in the cylinder is  
noclear, the gas processing / gas disposal company musbe  
informed of this  
⇒ “2.13 Filling contaminated refrigeranin a recycling cylinder  
for analysis, processing or disposal”, page 161 and  
⇒ “6.2.17 Returning contaminated R1234yf refrigeranfor  
analysis, processing or disposal”, page 25 .  
CAUTION  
Risk of explosion from overfilling refrigeranreservoirs.  
Refrigerancan expand and cause reservoirs to bursif they are  
overfilled.  
– Use a refrigerantank with safety valve.  
– Never exceed the permissible fill level of the refrigerantank.  
There are various ways to empty an air conditioner service sta‐  
tion , observe the operating instructions of the air conditioner  
154  
Rep. gr.87 - Air conditioning system  