Advertisement

Advertisement

Technical data -> 1.1 Safety precautions when working on air conditioning systems for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
00 – Technical data  
1
Safety information  
(VRL010467; Edition 07.2017)  
⇒ “1.1 Safety precautions when working on air conditioning sys‐  
tems”, page 1  
⇒ “1.2 Safety precautions when handling refrigerants”,  
page 1  
⇒ “1.3 Safety measures when working on vehicles with a start/  
stop system”, page 2  
⇒ “1.4 Safety measures when using air conditioner service sta‐  
tions”, page 2  
⇒ “1.5 Safety measures for working on vehicles with high-voltage  
system”, page 3  
⇒ “1.6 Safety precautions when working in the vicinity of high-  
voltage components”, page 4  
⇒ “1.7 Safety measures when working on pressurised tanks/con‐  
tainers”, page 4  
lk  
1.1  
Safety precautions when working on air conditioning systems  
Risk of fatal injury and explosion from sources of ignition  
Risk of fatal injury and explosion from sources of ignition in the  
vicinity of air conditioning systems and refrigerant tanks. Escap‐  
ing refrigerant could ignite and cause an explosion. Risk of ex‐  
plosion leading to loss of life or serious injuries.  
– Never bring sources of ignition close to air conditioning sys‐  
tems and refrigerant tanks.  
– Avoid electrostatic discharge, sparks from tools striking sur‐  
faces and hot surfaces.  
Risk of damage to refrigerant lines  
There is a risk of damage to the refrigerant lines due to rupture of  
the inner foil.  
– Never bend refrigerant lines to a radius less than 100 mm.  
1.2  
Safety precautions when handling refrigerants  
Risk of suffocation and poisoning from refrigerant  
Coughing and nausea leading to suffocation and poisoning from  
refrigerant vapours possible.  
– Never inhale refrigerant vapours.  
– Only work on the refrigerant circuit and refrigerant tanks in well  
ventilated areas.  
– Never work in or near cellars or other low lying areas.  
– Switch on the extraction system.  
1. Safety information  
1