Advertisement

Advertisement

Technical data -> 3.3 Refrigerant and refrigerant oil for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
3.3  
Refrigerant and refrigerant oil  
⇒ “3.3.1 Important repair instructions for refrigerant and refriger‐  
ant oil”, page 9  
⇒ “3.3.2 Refrigerant oil”, page 9  
3.3.1  
Important repair instructions for refriger‐  
ant and refrigerant oil  
An air conditioner designed for R1234yf refrigerant must never  
be charged with R134a refrigerant.  
An air conditioner designed for R134a refrigerant must never  
be charged with R1234yf refrigerant.  
The refrigerant oils especially developed for refrigerant circuits  
with R1234yf and R134a refrigerant may not be used in a re‐  
frigerant circuit charged with a different refrigerant unless the  
relevant permissions have been granted ⇒ Electronic parts  
catalogue and ⇒ Heating, air conditioning system; Rep. gr.  
lk  
00 ; Technical data; refrigerant oil .  
Air conditioner service stations which come in contact with re‐  
frigerant may only be used for the target refrigerant.  
A label -A- is attached in the engine compartment to the lock  
carrier or the plenum chamber to provide information on the  
refrigerant used.  
Different refrigerants must never be mixed.  
Depending on the type and production period, it may also in‐  
dicate the GWP for the refrigerant used.  
To ensure that only R1234yf refrigerant with a certain purity  
level is drawn into the air conditioner service station (R1234yf),  
a gas analysis must be performed before the refrigerant circuit  
is emptied  
⇒ “2.3 Performing gas analysis of refrigerant”, page 134 .  
Note  
If, during the gas analysis, it is found that the R1234yf refrigerant  
is contaminated with a different gas, it must be extracted from the  
refrigerant circuit and analysed, processed or disposed of as gas  
of unknown composition in accordance with the legal require‐  
ments ⇒ VW / Audi ServiceNet ,  
⇒ “2.3 Performing gas analysis of refrigerant”, page 134 and  
⇒ “6.2.17 Returning contaminated R1234yf refrigerant for analy‐  
sis, processing or disposal”, page 25 .  
3.3.2  
Refrigerant oil  
CAUTION  
Risk of chemical burns from atomised refrigerant oil. Eyes and  
other parts of the body could be injured.  
– Wear protective gloves.  
– Wear protective goggles.  
– Never inhale atomised refrigerant oil.  
♦ Refrigerant oil mixes with the refrigerant (about 10 to 40%,  
depending on compressor type and amount of refrigerant) and  
circulates constantly in the system, lubricating the moving  
parts.  
3. Repair notes  
9
GETth  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
♦ Special synthetic refrigerant machine oils such as polyalky‐  
lene glycol (PAG) oil with certain additives adapted to the  
refrigerant oil are used in conjunction with R1234yf air condi‐  
tioning systems. This is necessary because e.g. mineral oil  
does not mix with R1234yf and, should the additives be miss‐  
ing, undesired reactions with the refrigerant or components of  
the refrigerant circuit could occur. In addition, the components  
of the R1234yf air conditioning system could be attacked if the  
mixture circulated within the refrigerant circuit under pressure  
and at high temperatures, or the lubricant film in the air con‐  
ditioner compressor broke down. The use of non-approved  
oils can lead to failure of the air conditioning system. There‐  
fore, use only approved refrigerant oils ⇒ Electronic parts  
catalogue .  
♦ Type of oil for R1234yf refrigerant in motor vehicles: PAG oil  
with specific additives adapted to R1234yf refrigerant (polyal‐  
kylene glycol with certain additives).  
♦ The most important properties are high solubility with refriger‐  
ant, good lubricating quality, absence of acid and low water  
lk  
content. For this reason, only very specific oils may be used.  
List of approved refrigerant oils and capacities ⇒ Electronic  
parts catalogue and ⇒ Heating, air conditioning system; Rep.  
gr. 00 ; Technical data (vehicle-specific workshop manual).  
♦ The PAG oils suitable for refrigerant R1234yf are heavily hy‐  
groscopic and cannot always be mixed with other oils. There‐  
fore, only use approved refrigerant oils.  
♦ Moisture and acids promote ageing of refrigerant oil, causing  
it to become dark, viscous and aggressive towards metals.  
Containers for refrigerant oil should therefore be kept closed  
to prevent the ingress of moisture. When containers are  
opened, they should be closed again immediately.  
♦ Due to its chemical properties, refrigerant oil must not be dis‐  
posed of together with engine oil or gear oil. Refrigerant oil is  
to be disposed of as waste oil of unknown origin (observe local  
regulations) ⇒ VW / Audi ServiceNet .  
♦ For refrigerant circuits with R1234yf refrigerant circuit, only  
approved oils may be used for this refrigerant and the air con‐  
ditioner compressor installed in the system ⇒ Electronic parts  
catalogue and ⇒ Heating, air conditioning system; Rep. gr.  
00 ; Technical data .  
♦ Refrigerant oil that was developed for R134a refrigerant is not  
suitable for refrigerant circuits with R1234yf refrigerant (as it  
is missing specific additives). Therefore, ensure that the cor‐  
rect type is used ⇒ Electronic parts catalogue and ⇒ Heating,  
air conditioning system; Rep. gr. 00 ; Technical data; Refrig‐  
erant oil .  
♦ Refrigerant oil that was developed for R1234yf refrigerant  
could also be suitable for use in refrigerant circuits with R134a  
refrigerant. Observe notes ⇒ Electronic parts catalogue and  
⇒ Heating, air conditioning system; Rep. gr. 00 ; Technical  
data (vehicle-specific workshop manual).  
Note  
The cylinder in which the refrigerant oil is supplied has a label  
from which the expiry date of the refrigerant oil can be gleaned.  
This expiry date is not critical if the cylinder is sealed tight.  
Refrigerant oil from a tightly sealed cylinder can also be used  
after the expiry date specified on the cylinder.  
10  
Rep. gr.00 - Technical data  
GETth  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
Do not store refrigerant oils open to the atmosphere as they  
are very hygroscopic (they readily absorb water).  
Always keep the refrigerant oil container and the refrigerant  
circuit sealed.  
Do not use ester oils (POE oils) as these are currently only  
compatible with larger systems under different operating con‐  
ditions (not suitable for motor vehicle air conditioning sys‐  
tems).  
3.4  
Handling pressurised tanks/containers  
Keep containers tightly sealed in a well ventilated, cool location.  
Refrigerant is heavier than air. Should gas escape from a system,  
it collects at ground level in particular.  
Protect against heat and direct sunlight, do not keep in areas with  
temperatures higher than 50°C.  
Do not keep in or near cellars or other low lying areas.  
Only keep in areas with an adequate flow of air.  
Keep containers away from sources of ignition.  
lk  
Smoking is forbidden in areas in which R1234yf refrigerant is  
kept. Also take measures to prevent electrostatic discharge.  
Secure containers to prevent them falling over.  
Secure upright cylinders to stop them falling over and cylinders  
lying flat to stop them rolling away.  
Containers must never be thrown.  
If they should fall, the containers may become severely deformed  
and break open. The refrigerant evaporates immediately, liberat‐  
ing considerable force. Flying fragments of cylinders can cause  
severe injuries.  
To protect cylinder valves, cylinders are only to be transported  
with a protective cap screwed on.  
Valves may break off if cylinders are not properly transported.  
Do not place near radiators!  
High temperatures can occur near radiators. High temperatures  
are also associated with high pressures and the maximum per‐  
missible tank pressure may be exceeded.  
Do not heat up above 50°C  
To mitigate any risk, the pressure vessel regulations stipulate that  
tanks/containers must not be heated up above 50°C.  
Do not expose to uncontrolled heat  
Do not heat with a naked flame under any circumstances. The  
local overheating that will result can change the structure of the  
container's materials, thereby reducing the safe maximum pres‐  
sure limit of the container. There is also a danger of the refrigerant  
decomposing due to localised overheating.  
Seal empty tanks/containers  
Empty refrigerant tanks/containers must always be closed to pre‐  
vent the ingress of moisture. Moisture causes steel tanks/con‐  
tainers to rust. Rust weakens the tank/container walls. In addition,  
3. Repair notes  
11  
GETth  