Advertisement

Advertisement

Technical data -> 1.3 Safety measures when working on vehicles with a start/stop system for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Risk of freezing injury from refrigerant  
When working on the air conditioning system, there is a risk of  
highly pressurised refrigerant escaping from the system. There is  
a risk of injury to the skin and parts of the body due to freezing.  
– Wear protective gloves.  
– Wear protective goggles.  
– Extract refrigerant and open the refrigerant circuit immediately  
afterwards.  
– If more than 10 minutes have passed since the refrigerant was  
extracted, repeat the extraction process before opening the  
refrigerant circuit. Pressure could build up in the refrigerant  
circuit from continued evaporation.  
1.3  
Safety measures when working on vehicles with a start/stop system  
Risk of injury due to unexpected motor start  
lk  
If the vehicle’s start/stop system is activated, the engine can start  
unexpectedly. A message in the dash panel insert indicates  
whether the start/stop system is activated.  
– Deactivate start/stop system by switching off the ignition.  
1.4  
Safety measures when using air condi‐  
tioner service stations  
Before connecting the charging system to the air conditioner,  
make sure that all existing shut-off valves are closed.  
Before the air conditioner service station is decoupled from the  
air conditioning system, ensure that the process is complete.  
This will prevent any more refrigerant than necessary and  
technically unavoidable from entering the atmosphere.  
Once the purified refrigerant from the air conditioner service  
station /extraction system has been filled into an external com‐  
pressed-gas cylinder, close the hand shut-off valves at the  
cylinder and charging system.  
Do not expose the air conditioner service station , extracting  
and charging system to moisture and do not use in a damp  
environment.  
Before performing any maintenance work on the air condition‐  
er service station , disconnect the extracting and charging  
system from the power supply.  
To reduce the risk of fire, avoid using an extension cable. If  
the use an extension cable is unavoidable, use an extension  
2
cable with a cross-section of at least 2.5 mm .  
In case of fire, remove external cylinder.  
If oil is drawn out of the air conditioning system by the suction  
accumulator of the air conditioner service station and emptied  
into the supplied measuring beaker, ensure that it is poured  
into a sealable container afterwards as the oil could contain a  
small amount of refrigerant. Refrigerant must not be released  
into the environment.  
2
Rep. gr.00 - Technical data  
GETth  

Related Topics