Advertisement

Advertisement

Download User Manual App

Quickly access user manual for free!

Charging -> Battery Charger VAS5900 for Your Audi A1 SUV 2010-2017

Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
3.2  
Battery Charger - VAS5900-  
⇒ “3.2.1 General Information”, page 31  
⇒ “3.2.2 Battery Charger VAS5900 Device Description”,  
page 32  
⇒ “3.2.3 Battery, Charging with Battery Charger VAS5900 ”, page  
32  
⇒ “3.2.4 Battery Charger VAS5900 Service Charge”, page 34  
⇒ “3.2.5 Severely Discharged Battery, Charging with Battery  
Charger VAS5900 ”, page 37  
⇒ “3.2.6 Battery Charger VAS5900 Support Mode”, page 38  
⇒ “3.2.7 Battery Charger VAS5900 Maintenance Charging”, page  
40  
3.2.1  
General Information  
WARNING  
Risk of injury. Follow all warning messages and safety pre‐  
cautions.  
Refer  
to  
⇒ “1.3 Warnings and Safety Precautions”, page 3 .  
WARNING  
Do not check or charge a Battery - A- when the visual indicator  
has »no color or is bright yellow«. Jump starting must not be  
used!  
There is a risk of explosion during testing, charging or jump  
starting.  
These Batteries - A- must be replaced.  
The charge current for the -VAS5900- can be read directly on the  
-VAS5900- .  
Note  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
Observe the -VAS5900- Operating Instructions.  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability  
with respect to the correctness of information in this document. Copyright by AUDI AG.  
♦ -VAS5900- device description. Refer to  
⇒ “3.2.2 Battery Charger VAS5900 Device Description”, page  
32 .  
♦ Charge the Battery - A- . Refer to  
⇒ “3.2.3 Battery, Charging with Battery Charger VAS5900 ”,  
page 32 .  
♦ Service charge. Refer to  
⇒ “3.2.4 Battery Charger VAS5900 Service Charge”,  
page 34 .  
♦ Severely discharged Battery - A- , charging. Refer to  
⇒ “3.2.5 Severely Discharged Battery, Charging with Battery  
Charger VAS5900 ”, page 37 .  
♦ Support mode. Refer to  
⇒ “3.2.6 Battery Charger VAS5900 Support Mode”,  
page 38 .  
3. Battery, Charging  
31  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
♦ Maintenance charging. Refer to  
⇒ “3.2.7 Battery Charger VAS5900 Maintenance Charging”,  
page 40 .  
3.2.2  
Battery Charger - VAS5900- Device De‐  
scription  
The -VAS5900- is designed to charge all 12 V Batteries - A- in the  
VW group.  
-VAS5900-  
Protected by copyrighthole, is not  
permitted unless authany liability  
with respect to the cUDI AG.  
Control Field Overview  
1 - Display  
2 - -button “Up”  
3 - -button “Down”  
4 - START/STOP -button  
5 - INFO -button  
3.2.3  
Battery, Charging with Battery Charger  
- VAS5900-  
Special tools and workshop equipment required  
♦ Battery Charger - VAS5900-  
WARNING  
Risk of injury. Follow all warning messages and safety pre‐  
cautions.  
Refer  
to  
⇒ “1.3 Warnings and Safety Precautions”, page 3 .  
WARNING  
Do not check or charge a Battery - A- when the visual indicator  
has »no color or is bright yellow«. Jump starting must not be  
used!  
There is a risk of explosion during testing, charging or jump  
starting.  
These Batteries - A- must be replaced.  
32  
Rep. Gr.27 - Starter, Generator and Cruise Control  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
Note  
The Battery - A- temperature must be at least 10 °C (50 °F).  
Procedure  
– Turn off the ignition and all electrical consumers and remove  
the ignition key.  
– Connect the -VAS5900- to the power supply. The last selected  
mode is shown on the display. Refer to  
⇒ “3.2.2 Battery Charger VAS5900 Device Description”, page  
32 .  
– Set the battery type with the INFO button.  
The symbol -1- for “standard charge of wet batteries” or the sym‐  
bol -2- for “standard charge of Gel/Absorbent Glass Mat (AGM)  
batteries” is indicated in the display.  
– Set the battery capacity (Ah) on the Battery - A- to be charged  
with the corresponding button or button.  
– Connect the red charge terminal (+) to the positive terminal of  
the Battery - A- .  
Note  
On vehicles with a Start/Stop function and an installed Battery  
Monitoring Control Module - J367- , the black charge terminal (-)  
must be connected to the body ground. The Start/Stop system  
will malfunction when it is connected to the Battery - A- negative  
terminal.  
– Connect the black charge terminal (-) to the negative terminal  
of the Battery - A- /negative connector.  
The -VAS5900- recognizes the nominal voltage of the connected  
Battery - A- (6 V/12 V/24 V) and begins the charging process au‐  
tomatically.  
The -VAS5900- begins Pthroetectfeidnbaylccophyarigrhgt.inCogpyiwnghfoernpritvhatee ocr hcoamrmgeercilael vpuerploses, in part or in whole, is not  
permitted unless authorised by AUDI AG. AUDI AG does not guarante
with respect to the correctness of information in this document. Copy
is approximately 80 to 85%. The fourth bar is indicated on the  
display -1-. The Battery - A- is ready to be used.  
3. Battery, Charging  
33  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
With a charge status of 100%, all bars are indicated on the display  
-1-.  
Note  
With the “standard charge”, parallel operation of electrical con‐  
sumers during the charging process is possible. The charging  
time is lengthened by this.  
Depending on the battery type, the -VAS5900- switches to  
maintenance charging after 1 to 7 hours. To reach a 100%  
charge level, the Battery - A- should remain connected to the  
-VAS5900- .  
Possible malfunctions and how they are handled  
1 - Displayed voltage does not match the nominal voltage:  
– Hold down the button or button until the charging process  
begins.  
2 - Displayed battery voltage does not match the nominal volt‐  
age - the charging process has already begun:  
– Press the START/STOP button two times.  
– Hold down the button or button until the charging process  
begins again.  
3 - The Battery Charger - VAS5900- does not recognize the  
Battery - A- , if the battery voltage is less than 2V:  
The display remains unchanged.  
The selected battery type and Ampere hours (Ah) are displayed.  
Battery - A- charging, ending  
– Press the START/STOP -button.  
– Remove the charging clamps from the battery terminals.  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability  
with respect to the correctness of information in this document. Copyright by AUDI AG.  
– Disconnect the -VAS5900- from the power.  
3.2.4  
Battery Charger - VAS5900- Service  
Charge  
Special tools and workshop equipment required  
♦ Battery Charger - VAS5900-  
WARNING  
Risk of injury. Follow all warning messages and safety pre‐  
cautions.  
Refer  
to  
⇒ “1.3 Warnings and Safety Precautions”, page 3 .  
Caution  
“Service charging” is not permitted for VW vehicles, because  
voltage surges can damage the on-board electronics.  
The Battery - A- must always be disconnected from the vehicle  
electrical system when using the “service charge” mode.  
34  
Rep. Gr.27 - Starter, Generator and Cruise Control  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
WARNING  
Do not check or charge a Battery - A- when the visual indicator  
has »no color or is bright yellow«. Jump starting must not be  
used!  
There is a risk of explosion during testing, charging or jump  
starting.  
These Batteries - A- must be replaced.  
Caution  
Always set the mode that corresponds to the Battery - A- during  
the charging process. Refer to the -VAS5900- Operating In‐  
structions.  
“Service Charging” is suitable for:  
♦ Wet batteries having a visual indicator which allows charg‐  
ing (visual indicator black or green).  
The “Service charge (SERV)” mode is only used with sulfated  
Batteries - A- . The Battery - A- with voltages greater than 14.4 V  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
is charged. A partial removal of the sulfation layer can result from  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability  
this. Check the visual indicator after charging, immediately before  
with respect to the correctness of information in this document. Copyright by AUDI AG.  
the Battery - A- is used. Refer to  
⇒ “2.3 Visual Indicator Color Display, Checking”, page 9 .  
Note  
The Battery - A- temperature must be at least 10 °C (50 °F).  
Procedure  
– Turn off the ignition and all electrical consumers and remove  
the ignition key.  
– Connect the -VAS5900- to the power supply. The last selected  
mode is shown on the display. Refer to  
⇒ “3.2.2 Battery Charger VAS5900 Device Description”, page  
32 .  
3. Battery, Charging  
35  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
– Set the battery type with the INFO button.  
The symbol -1- for “service charge of wet batteries” or the symbol  
-2- for “service charge of Gel/Absorbent Glass Mat (AGM) bat‐  
teries” is indicated in the display.  
– Set the battery capacity (Ah) on the Battery - A- to be charged  
with the corresponding button or button.  
– Connect the red charge terminal (+) to the positive terminal of  
the Battery - A- .  
Note  
On vehicles with a Start/Stop function and an installed Battery  
Monitoring Control Module - J367- , the black charge terminal (-)  
must be connected to the body ground. The Start/Stop system  
will malfunction when it is connected to the Battery - A- negative  
terminal.  
– Connect the black charge terminal (-) to the negative terminal  
of the Battery - A- /negative connector.  
The -VAS5900- recognizes the nominal voltage of the connected  
Battery - A- (6 V/12 V/24 V) and begins the charging process au‐  
tomatically.  
The -VAS5900- begins the “final charging” when the charge level  
is approximately 80 to 85 % of the battery voltage. The fourth bar  
is indicated on the display -1-. The Battery - A- is now ready to be  
used.  
Note  
A successful “service charge” depends on the degree of sulfation  
on the Battery - A- .  
Possible malfunctions and how they are handled  
1 - Displayed voltage does not match the nominal voltage:  
– Hold down the button or button until the charging process  
begins.  
2 - Displayed battery voltage does not match the nominal volt‐  
age - the charging process has already begun:  
– Press the START/STOP button two times.  
– Hold down the button or button until the charging process  
begins.  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability  
with respect to the correctness of information in this document. Copyright by AUDI AG.  
3 - The charger does not recognize a Battery - A- , when the  
battery voltage is less than 2 V:  
The display remains unchanged.  
The set operating mode and Ampere-hours (Ah) are displayed.  
Battery - A- charging, ending  
– Press the START/STOP -button.  
– Remove the charging clamps from the battery terminals.  
– Disconnect the -VAS5900- from the power.  
36  
Rep. Gr.27 - Starter, Generator and Cruise Control  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
3.2.5  
Severely Discharged Battery, Charging  
with Battery Charger - VAS5900-  
Special tools and workshop equipment required  
♦ Battery Charger - VAS5900-  
WARNING  
Risk of injury. Follow all warning messages and safety pre‐  
cautions.  
Refer  
to  
⇒ “1.3 Warnings and Safety Precautions”, page 3 .  
WARNING  
Do not check or charge a Battery - A- when the visual indicator  
has »no color or is bright yellow«. Jump starting must not be  
used!  
There is a risk of explosion during testing, charging or jump  
starting.  
These Batteries - A- must be replaced.  
Caution  
♦ The polarity protection of the charger clamps is not active  
in the operation mode “charging severely discharged bat‐  
teries/Support mode”. Connect the charger clamps to the  
battery terminals correctly according to polarity!  
♦ Always set the mode that corresponds to the Battery - A-  
during the charging process. Refer to the -VAS5900- Op‐  
erating Instructions.  
♦ The -VAS5900- does not recognize the severely dis‐  
charged Battery - A- . Refer to  
⇒ “3.6 Severely Discharged Batteries”, page 57 .  
♦ Do not touch START / STOP button when battery cables  
are incorrectly connected! The -VAS5900- can become  
damaged.  
The -VAS5900- will not automatically recognize the Battery - A-  
for Batteries - A- with a voltage less than 2 V.  
Note  
For information in the chapter. Refer to  
⇒ “3.6 Severely Discharged Batteries”, page 57 .  
The Battery - A- temperature must be at least 10 °C (50 °F).  
Severely discharged batteries in vehicles must be replaced  
prior to delivery. Pre-existing damage cannot be ruled out.  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability  
with respect to the correctness of information in this document. Copyright by AUDI AG.  
Procedure  
– Turn off the ignition and all electrical consumers and remove  
the ignition key.  
– Connect the -VAS5900- to the power supply. The last selected  
mode is shown on the display. Refer to  
3. Battery, Charging  
37  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
⇒ “3.2.2 Battery Charger VAS5900 Device Description”, page  
32 .  
– Set the battery type with the INFO button.  
The symbol -1- for “service charge of wet batteries” or the symbol  
-2- for “service charge of Gel/Absorbent Glass Mat (AGM) bat‐  
teries” is indicated in the display.  
– Set the battery capacity (Ah) on the Battery - A- to be charged  
with the corresponding button or button.  
– Connect the red charge terminal (+) to the positive terminal of  
the Battery - A- .  
Note  
On vehicles with a Start/Stop function and an installed Battery  
Monitoring Control Module - J367- , the black charge terminal (-)  
must be connected to the body ground. The Start/Stop system  
will malfunction when it is connected to the Battery - A- negative  
terminal.  
– Connect the black charge terminal (-) to the negative terminal  
of the Battery - A- /negative connector.  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
– Press the START/STOP button for about 5 seconds. The menu  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability  
selectiownithCreshpaecrtgtointhge csoerrvecetnreeslsyofdinifsocrmhaatiorngien dthisbdaotctuemreinet.sC/SopuyrpigphtobrytAUDI AG.  
mode” is activated.  
– Press the corresponding -button or button to adjust the  
battery voltage (6 V/12 V/24 V).  
Note  
If no button is touched within five seconds, the -VAS5900- will  
return to the main menu (operating mode selection).  
– Select the battery voltage by pressing the START/STOP button.  
Then the inquiry about the correct polarity of the charging clamps  
is made.  
– Check correct polarity connection of charger clamps.  
– Confirm charging clamps are connected to correct poles via  
START/STOP button.  
The -VAS5900- starts to charge the severely discharged Battery  
- A- .  
Battery - A- charging, ending  
– Press the START/STOP -button.  
– Remove the charging clamps from the battery terminals.  
– Disconnect the -VAS5900- from the power.  
3.2.6  
Battery Charger - VAS5900- Support  
Mode  
Special tools and workshop equipment required  
♦ Battery Charger - VAS5900-  
38  
Rep. Gr.27 - Starter, Generator and Cruise Control  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
General Information  
The support mode provides the vehicle electrical system with  
voltage when the Battery - A- is removed or disconnected.  
For more information. Refer to the -VAS5900- Operating Instruc‐  
tions.  
The support mode is used for the following situations:  
♦ Vehicle electrical system support mode with the Battery - A-  
not installed  
♦ Maintaining the voltage when the battery is being replaced  
♦ Systems test without the Battery - A-  
WARNING  
Risk of injury. Follow all warning messages and safety pre‐  
cautions.  
Refer  
to  
⇒ “1.3 Warnings and Safety Precautions”, page 3 .  
WARNING  
Do not check or charge a Battery - A- when the visual indicator  
has »no color or is bright yellow«. Jump starting must not be  
used!  
There is a risk of explosion during testing, charging or jump  
starting.  
These Batteries - A- must be replaced.  
Procedure  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability  
with respect to the correctness of information in this document. Copyright by AUDI AG.  
Caution  
♦ The polarity protection of the charger clamps is not active  
in the operation mode “charging severely discharged bat‐  
teries/Support mode”. Connect the charger clamps to the  
battery terminals correctly according to polarity!  
♦ It can result in sparks due to short circuit.  
♦ This constitutes an explosion risk.  
♦ Do not touch START / STOP button when battery cables  
are incorrectly connected! The -VAS5900- can become  
damaged.  
– Remove the Battery - A- . Refer to ⇒ Electrical Equipment;  
Rep. Gr. 27 ; Battery; Battery, Removing and Installing .  
– Connect the -VAS5900- to the power supply. The last selected  
mode is shown on the display. Refer to  
⇒ “3.2.2 Battery Charger VAS5900 Device Description”, page  
32 .  
3. Battery, Charging  
39  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
Caution  
Whenever the Battery - A- is removed, be careful to prevent  
contact between the connected charge clamp on the positive  
terminal and the body ground. Likewise prevent contact be‐  
tween the battery terminals.  
– Connect the red charge terminal (+) to the positive terminal of  
the Battery - A- .  
Note  
On vehicles with a Start/Stop function and an installed Battery  
Monitoring Control Module - J367- , the black charge terminal (-)  
must be connected to the body ground. The Start/Stop system  
will malfunction when it is connected to the Battery - A- negative  
terminal.  
– Connect the black charge terminal (-) to the negative terminal  
of the Battery - A- /negative connector.  
– Press the START/STOP button for about 5 seconds. The menu  
selection “Charging severely discharged batteries/Support  
mode” is activated.  
– Press the corresponding -button or button to adjust the  
battery voltage (6 V/12 V/24 V).  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability  
Note  
If no button is touched withiwnithfirveespescet tcoothnedcosr,retchtneessBoaf itntfeorrmyatCionhian rthgisedroc-ument. Copyright by AUDI AG.  
VAS5900- will return to the main menu (operating mode selec‐  
tion).  
– Select the battery voltage by pressing the START/STOP button.  
Then the inquiry about the correct polarity of the charging clamps  
is made.  
– Check correct polarity connection of charger clamps.  
– Confirm charging clamps are connected to correct poles via  
START/STOP button.  
The -VAS5900- starts the Battery - A- support mode.  
End the Battery Support Mode  
– Press the START/STOP -button.  
– Remove the charging clamps from the battery terminals.  
– Disconnect the -VAS5900- from the power.  
3.2.7  
Battery Charger - VAS5900- Mainte‐  
nance Charging  
Special tools and workshop equipment required  
♦ Battery Charger - VAS5900-  
40  
Rep. Gr.27 - Starter, Generator and Cruise Control  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
Note  
If the Battery - A- is discharged by an electrical consumer dur‐  
ing maintenance charging, the -VAS5900- automatically sup‐  
plies the appropriate charge.  
Maintenance charging can be performed without time restric‐  
tions.  
The Battery - A- can be used constantly.  
Observe the maintenance notes of the battery manufacturer.  
WARNING  
Risk of injury. Follow all warning messages and safety pre‐  
cautions.  
Refer  
to  
⇒ “1.3 Warnings and Safety Precautions”, page 3 .  
WARNING  
Do not check or charge a Battery - A- when the visual indicator  
has »no color or is bright yellow«. Jump starting must not be  
used!  
There is a risk of explosion during testing, charging or jump  
starting.  
These Batteries - A- must be replaced.  
If the Battery - A- is fully charged, the -VAS5900- starts mainte‐  
nance charging.  
Procedure  
– Proceed as if charging the Battery - A- . Refer to  
⇒ “3.2.3 Battery, Charging with Battery Charger VAS5900 ”,  
page 32 .  
With a charge status of 100%, all bars are indicated on the display  
-1-.  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liab
with respect to the correctness of information in this document. Copyright by AUDI AG.  
3. Battery, Charging  
41  

Related Topics