Checking -> Current Draw Test for Your Audi A1 SUV 2010-2017

Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
2.6.6  
Printed Test Results Explanations  
1 - Measuring range set on the -VAS5097A-  
2 - Diagram, the -arrow- points to the Battery - A- status.  
3 - Test result  
4 - Battery - A- voltage during the battery load test.  
5 - Vehicle data and date. For tester to fill out.  
Note  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is no
The printed test results are required for warranty claims.  
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liabilit
Only perwfoithrmrespthecet ttoethsetcoornreccetn.esRs eofpinefoarmtiantigontihn ethistedosctuwmeilnlt.nCootpyprirgohtdbuy cAUeDI AG.  
accurate results.  
2.6.7  
Test Result Evaluation  
Printout  
Measures  
Starting power very good  
Starting power good  
Battery - A- is OK.  
Battery - A- is OK.  
Starting power sufficient  
Evaluation performed by the  
current draw test. Refer to  
⇒ “2.7 Current Draw Test”,  
page 22 .  
Starting power insufficient  
Evaluation performed by the  
current draw test. Refer to  
⇒ “2.7 Current Draw Test”,  
page 22 .  
Starting power very insufficient Evaluation performed by the  
current draw test. Refer to  
⇒ “2.7 Current Draw Test”,  
page 22 .  
Cannot be tested  
– Charge the Battery - A-  
and perform the test again.  
Refer to  
⇒ “3 Battery, Charging”,  
page 25 .  
2.7  
Current Draw Test  
WARNING  
Do not check or charge a Battery - A- when the visual indicator  
has »no color or is bright yellow«. Jump starting must not be  
used!  
There is a risk of explosion during testing, charging or jump  
starting.  
These Batteries - A- must be replaced.  
Make sure the correct charging mode is set on the battery charger  
so the current draw test is not inaccurate.  
♦ -VAS5095A- . Refer to  
⇒ “3.1.3 Battery, Charging with Battery Charger VAS5095A ”,  
page 26 .  
22  
Rep. Gr.27 - Starter, Generator and Cruise Control  
Audi A1 2011 ➤ , Audi A1 Sportback 2018 ➤ , Audi A2 2001 ➤ , Audi A3 20 ...  
Electrical Equipment General Information - Edition 08.2019  
♦ -VAS5900- . Refer to  
⇒ “3.2 Battery Charger VAS5900 ”, page 31 .  
♦ -VAS5903- . Refer to  
⇒ “3.3 Battery Charger VAS5903 ”, page 42 .  
In order to receive an indication as quickly as possible of the bat‐  
tery condition of discharged Batteries - A- , a conclusion can be  
made during the charging process using the Battery - A- current  
draw as to whether the Battery - A- should be replaced or charged  
completely.  
Note  
In the case of the -VAS6161- , the current draw test must always  
be conducted when the test result “conduct current draw test” ap‐  
pears in the display.  
The current draw test should always be performed if the test using  
the -VAS5097A- had the following results:  
1 - Starting power sufficient  
2 - Starting power insufficient  
3 - Starting power very insufficient  
4 - Cannot be tested - charge the Battery - A- and perform the  
test again  
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not  
5 - -VAS50p9e7rmAitt-edduonelesssnauothtotruiserdnboy nAU(DnI oAGL. AEUDDI,AnGodopersinnottoguuatr)antee or accept any liability  
with respect to the correctness of information in this document. Copyright by AUDI AG.  
Depending on the test results -VAS5097A- (refer to  
⇒ “2.6.7 Test Result Evaluation”, page 22 ), additional test steps  
or work for a clear evaluation of the battery charge must be made.  
By checking a current draw capacity on a Battery - A- during the  
charging procedure, it can be determined in a short time whether  
a partially discharged or severely discharged Battery - A- can be‐  
come operable again by further charging. Refer to  
⇒ “3.6 Severely Discharged Batteries”, page 57 .  
Test Prerequisites  
♦ When charging a battery, the temperature of the battery must  
be at least 10 °C (50 °F).  
♦ The charger must be able to deliver at least 30 A charge cur‐  
rent, such as on the -VAS5095A- / -VAS5900- / Battery Charg‐  
er - VAS5903- .  
♦ When charging with the -VAS5095A- , the Battery - A- current  
draw must be measured using a current probe ( -  
VAS6356/4A- ).  
♦ The -VAS5900- and the -VAS5903- indicate the current draw.  
Procedure  
– Connect the Battery - A- to the Battery Charger and start the  
charging process.  
– Measure the Battery - A- charge current after five minutes.  
Test Result  
The charge current must be above 10% of the nominal capacity  
5 minutes after charging begins.  
Example  
With a 60 Ah battery, the charge current must be greater than 6  
A 5 minutes after charging begins.  
2. Battery, Checking  
23  

Related Topics