Advertisement

Advertisement

Air conditioning system -> 1.2.10 Receiver for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

lk  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
1.2.10  
Receiver  
♦ The receiver -B- collects the liquid droplets and directs them  
in a continuous stream to the expansion valve. Any moisture  
that has entered the refrigerant circuit during assembly is col‐  
lected by a dryer -D- in the receiver -B-.  
♦ Depending on the layout of the refrigerant circuit and the ver‐  
sion of condenser -A-, the receiver -B- may be installed on the  
condenser -A- or (integrated) in the condenser -A- ⇒ Heating,  
air conditioning; Rep. gr. 87 ; Refrigerant circuit (vehicle-spe‐  
cific workshop manual) and ⇒ Electronic parts catalogue .  
♦ Installed in the receiver -B- is a dryer (e.g. desiccant bag -D-)  
and strainer -F- (that filters out smaller contaminants).  
Note  
The receiver -B- comes in different versions and different de‐  
signs ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant  
circuit (vehicle-specific workshop manual) and ⇒ Electronic  
parts catalogue .  
Renew the receiver -B- and plastic bolt (with seals) -C-, des‐  
iccant cartridge -D-, filter carrier -E- and strainer -F- if the  
refrigerant circuit was open for an extended period of time and  
moisture has been absorbed, or if required to do so owing to  
a specific complaint ⇒ page 79 .  
Do not remove the sealing plugs of a receiver until immediately  
prior to installation as a desiccant bag in a non-sealed reser‐  
voir will become saturated with moisture and become unusa‐  
ble.  
The desiccant cartridge comes in an air-tight transport bag,  
which should remain sealed for as long as possible. Do not  
open the transport bag until immediately prior to inserting the  
desiccant cartridge -D- in the receiver -B- of the condenser.  
After the transport bag has been opened, the desiccant car‐  
tridge will become saturated with moisture within a short time  
and is then unusable.  
When installing, observe arrow indicating direction of flow if  
applicable.  
The procedure to adopt in the event of a complaint differs de‐  
pending on the type of receiver/desiccant cartridge. If the  
receiver is installed on the condenser, for example, it can be  
renewed completely with the desiccant cartridge. If the receiv‐  
er is integrated in the condenser, for example, the desiccant  
cartridge and an additional filter element (if one is fitted) can  
be replaced individually on most versions. If the receiver is  
integrated in the condenser and it is not possible to replace  
the receiver/desiccant cartridge separately, it may be neces‐  
sary to replace the entire condenser ⇒ Heating, air condition‐  
ing; Rep. gr. 87 ; Refrigerant circuit (vehicle-specific workshop  
manual) and ⇒ Electronic parts catalogue .  
Depending on the layout of the refrigerant circuit (with desic‐  
cant bag or desiccant cartridge), the receiver may also be  
integrated in the refrigerant circuit (it need not always be in‐  
stalled on or in the condenser) ⇒ Heating, air conditioning;  
Rep. gr. 87 ; Refrigerant circuit (vehicle-specific workshop  
manual) and ⇒ Electronic parts catalogue .  
1. Refrigerant circuit  
47  
GETth  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
1.2.11  
Expansion valve (with and without shut-  
off valve)  
Expansion valve without shut-off function  
The expansion valve -A- atomises incoming refrigerant and reg‐  
ulates the flow so that, depending on the heat transport, the  
vapour does not become a gas until it reaches the outlet of the  
evaporator.  
Note  
When R1234yf refrigerant was introduced, the expansion  
valves were adapted to the refrigerant (different characteris‐  
tics), hence the need to observe the correct version ⇒ Elec‐  
tronic parts catalogue .  
Different versions of expansion valve due to different charac‐  
teristics that are matched to the relevant refrigerant circuit ⇒  
Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit (ve‐  
hicle-specific workshop manual) and ⇒ Electronic parts cata‐  
lk  
logue .  
When renewing the expansion valve, make sure that the part  
number is correct ⇒ Electronic parts catalogue .  
Depending on the version of air conditioner compressor, a  
valve may be installed on the high-pressure side that prevents  
liquefied refrigerant flowing back into the air conditioner com‐  
pressor after the air conditioning system is switched off. If an  
air conditioner compressor with this valve is installed in a ve‐  
hicle with a refrigerant circuit with expansion valve, it could  
take some time before the pressure on the high-pressure side  
drops (the expansion valve is cold and the pressure on the  
low-pressure side rises quickly after switching off, the expan‐  
sion valve closes and refrigerant only flows slowly on the low-  
pressure side). If the air conditioner compressor is switched  
on, the pressure on the low-pressure side drops, the expan‐  
sion valve opens and refrigerant can flow on the low-pressure  
side.  
Expansion valve with refrigerant shut-off valve  
Note  
Shut-off valves come in different versions, with different functions  
and different designations ⇒ Heating, air conditioning; Rep. gr.  
87 ; Refrigerant circuit (vehicle-specific workshop manual).  
48  
Rep. gr.87 - Air conditioning system  
GETth  

Related Topics