Air conditioning system -> 1.2.15 Seals for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
The quick release couplings come in different versions -A- and  
-D-. On both versions of these quick release couplings, the  
refrigerant lines -C- can be released and removed in the same  
way, e.g. with refrigerant line release tool -T40149/1- ⇒ Heat‐  
ing, air conditioning; Rep. gr. 87 ; Refrigerant circuit (vehicle-  
specific workshop manual).  
For quick release coupling version -A-, the control pins -B- be‐  
come visible after installing the refrigerant line -C- once the  
engaged refrigerant line -C- is pulled in the direction of arrow.  
For quick release coupling version -D-, the refrigerant line  
-C- is installed in the same way as quick release coupling  
-A-. When the refrigerant line -C- on this version is pulled in  
the direction of arrow following assembly, the snap ring -E-  
protrudes from the quick release coupling -D-, thereby indi‐  
cating that the retaining ring -F- is completely engaged with  
the refrigerant line -C-. The snap ring -E- must then be re‐  
moved from the refrigerant line -C-.  
1.2.15  
Seals  
♦ These seals seal the connection points between the individual  
components of the refrigerant circuit  
⇒ “3.2 Refrigerant circuit seals”, page 8 .  
1.2.16  
Pipes and hoses in refrigerant circuit  
♦ In its pure state, R1234yf refrigerant is chemically stable and  
has no corrosive effect on e.g. iron, aluminium and specially  
developed plastics that are suitable for this purpose. A mixture  
of refrigerant oil and R1234yf refrigerant can affect certain  
metals (e.g. alloys with copper) and affect or degrade certain  
hose materials and plastics. Therefore, use only genuine re‐  
placement parts ⇒ Electronic parts catalogue .  
♦ Only use components that are resistant to R1234yf refrigerant  
and its associated refrigerant oils. Do not use components  
(such as seals and hoses, which are made of plastic) that  
cannot be clearly allocated ⇒ Electronic parts catalogue .  
♦ The pipes and hoses are held together by threaded connec‐  
tions and / or special joints ⇒ Heating, air conditioning; Rep.  
gr. 87 ; Refrigerant circuit (vehicle-specific workshop manual).  
♦ Renew the sealing elements (e.g. seals) between the compo‐  
nents ⇒ Electronic parts catalogue .  
♦ For threaded connections, observe the specified torque set‐  
tings. For pressure-fit connections, use dedicated release  
tools ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant  
circuit (vehicle-specific workshop manual).  