Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017
Note
♦ In the event of internal damage (to the air conditioner com‐
pressor), check the refrigerant hoses and condenser. If con‐
taminated by swarf, for example, clean ltkhe refrigerant hoses
and condenser (flush with R1234yf refrigerant
⇒ “1.6 Cleaning refrigerant circuit”, page 92 ); renew refrig‐
erant hoses if necessary.
♦ On certain vehicles (e.g. vehicles with 2 evaporators), the vol‐
ume of refrigerant oil in the refrigerant circuit may be greater
than the volume in the replacement air conditioner compres‐
sor. Replenish the refrigerant circuit on these vehicles with the
amount of refrigerant oil necessary ⇒ Heating, air condition‐
ing; Rep. gr. 00 ; Technical data (vehicle-specific workshop
manual).
♦ In the event of a fault in the electronics of an electrical air con‐
ditioning compressor (e.g. control unit for air conditioning com‐
pressor - J842- defective), the refrigerant circuit need not be
flushed. In this case, the air conditioner compressor is to be
renewed without there being a requirement to clean the re‐
frigerant circuit
⇒ “1.5.4 Renewing air conditioner compressor with no need to
clean refrigerant circuit”, page 85
– Renew desiccant bag/desiccant cartridge (reservoir/receiver)
⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit;
System overview - refrigerant circuit .
– Check expansion valve for contamination or corrosion, renew
if necessary ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrig‐
erant circuit; System overview - refrigerant circuit .
– Assemble the refrigerant circuit, evacuate and charge
⇒ page 129 .
1.5.6
Renewing desiccant cartridge / receiver
after cleaning refrigerant circuit
Note
Installed in the receiver is usually a desiccant cartridge or desic‐
cant bag (depending on the layout of the refrigerant circuit) ⇒
Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit; System
overview - refrigerant circuit
♦ Observe the general information about renewing components
⇒ “1.5.1 General information about renewing components”,
page 79
Note
Clean the refrigerant circuit. In other words, flush with R1234yf
refrigerant ⇒ “1.6 Cleaning refrigerant circuit”, page 92 .
For example due to moisture ingress (the refrigerant circuit was
open for too long) or contamination
– Drain refrigerant circuit ⇒ page 129 .
– Remove air conditioner compressor ⇒ Heating, air condition‐
ing; Rep. gr. 87 ; Air conditioner compressor .
88
Rep. gr.87 - Air conditioning system