Advertisement

Advertisement

Air conditioning system -> 1.5.8 Renewing desiccant cartridge / desiccant bag with no need to clean refrigerant circuit for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
If for instance 50 cm3 refrigerant oil was poured out of the de‐  
fective air conditioner compressor, and 100 cm3 oil was pour‐  
ed out of the replacement air conditioner compressor (a small  
quantity of refrigerant oil remains in the air conditioner com‐  
pressor), pour 50 cm3 refrigerant oil into the replacement air  
conditioner compressor (the refrigerant oil previously poured  
from the air conditioner compressor spare part may be used).  
Different refrigerant oils and volumes for different air condi‐  
tioner compressors ⇒ Heating, air conditioning; Rep. gr. 00 ;  
Technical data .  
If quite a large amount of refrigerant oil was poured out of the  
defective air conditioner compressor (more than approx. 50  
cm 3), the remaining refrigerant oil can also be poured in the  
evaporator or reservoir/receiver/inner heat exchanger ⇒ Heat‐  
ing, air conditioning; Rep. gr. 87 ; Refrigerant circuit; System  
overview - refrigerant circuit .  
All  
lk  
– Renew restrictor (only if installed in this refrigerant circuit).  
– Assemble the refrigerant circuit, evacuate and charge  
⇒ page 129 .  
1.5.5  
Renewing air conditioner compressor  
due to leaks or internal damage  
♦ Observe the general information about renewing components  
⇒ “1.5.1 General information about renewing components”,  
page 79  
Vehicles with high-voltage system (hybrid vehicles)  
– Observe the risk category of the high-voltage system ⇒ Rep.  
gr. 00 ; Risk category of the high-voltage system .  
– Observe safety precautions when working on the high-voltage  
system  
⇒ “1.5 Safety measures for working on vehicles with high-volt‐  
age system”, page 3 .  
– Observe safety precautions when working in the vicinity of  
high-voltage components  
⇒ “1.6 Safety precautions when working in the vicinity of high-  
voltage components”, page 4 .  
All vehicles  
Renew air conditioner compressor e.g. owing to noise from the  
air conditioner compressor or lack of performance.  
– Drain refrigerant circuit ⇒ page 129 .  
– Remove air conditioner compressor ⇒ Heating, air condition‐  
ing; Rep. gr. 87 ; Air conditioner compressor .  
– Clean refrigerant circuit (flush with R1234yf refrigerant)  
⇒ “1.6 Cleaning refrigerant circuit”, page 92 .  
1. Refrigerant circuit  
87  
GETth  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
In the event of internal damage (to the air conditioner com‐  
pressor), check the refrigerant hoses and condenser. If con‐  
taminated by swarf, for example, clean ltkhe refrigerant hoses  
and condenser (flush with R1234yf refrigerant  
⇒ “1.6 Cleaning refrigerant circuit”, page 92 ); renew refrig‐  
erant hoses if necessary.  
On certain vehicles (e.g. vehicles with 2 evaporators), the vol‐  
ume of refrigerant oil in the refrigerant circuit may be greater  
than the volume in the replacement air conditioner compres‐  
sor. Replenish the refrigerant circuit on these vehicles with the  
amount of refrigerant oil necessary ⇒ Heating, air condition‐  
ing; Rep. gr. 00 ; Technical data (vehicle-specific workshop  
manual).  
In the event of a fault in the electronics of an electrical air con‐  
ditioning compressor (e.g. control unit for air conditioning com‐  
pressor - J842- defective), the refrigerant circuit need not be  
flushed. In this case, the air conditioner compressor is to be  
renewed without there being a requirement to clean the re‐  
frigerant circuit  
⇒ “1.5.4 Renewing air conditioner compressor with no need to  
clean refrigerant circuit”, page 85  
– Renew desiccant bag/desiccant cartridge (reservoir/receiver)  
⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit;  
System overview - refrigerant circuit .  
– Check expansion valve for contamination or corrosion, renew  
if necessary ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrig‐  
erant circuit; System overview - refrigerant circuit .  
– Assemble the refrigerant circuit, evacuate and charge  
⇒ page 129 .  
1.5.6  
Renewing desiccant cartridge / receiver  
after cleaning refrigerant circuit  
Note  
Installed in the receiver is usually a desiccant cartridge or desic‐  
cant bag (depending on the layout of the refrigerant circuit) ⇒  
Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit; System  
overview - refrigerant circuit  
♦ Observe the general information about renewing components  
⇒ “1.5.1 General information about renewing components”,  
page 79  
Note  
Clean the refrigerant circuit. In other words, flush with R1234yf  
refrigerant ⇒ “1.6 Cleaning refrigerant circuit”, page 92 .  
For example due to moisture ingress (the refrigerant circuit was  
open for too long) or contamination  
– Drain refrigerant circuit ⇒ page 129 .  
– Remove air conditioner compressor ⇒ Heating, air condition‐  
ing; Rep. gr. 87 ; Air conditioner compressor .  
88  
Rep. gr.87 - Air conditioning system  
GETth  