Air conditioning system -> 1.2.18 Non-return valves for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
1.2.18  
Non-return valves  
Non-return valves separate the refrigerant circuit into different  
areas ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit  
(vehicle-specific workshop manual).  
Note  
The non-return valve -3- shown in installed e.g. in the Audi Q7  
e-tron ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant  
circuit (vehicle-specific workshop manual).  
Non-return valves in the refrigerant circuit have a certain hold‐  
ing pressure in the direction of flow (approx. 0.1 bar or  
100 mbar). To ensure that the refrigerant circuit can be evac‐  
uated completely (residual pressure below 5 mbar), all of the  
electrically actuated valves must therefore be open.  
Depending on the version, the direction of flow may be indi‐  
cated by a sticker.  
lk  
54  
Rep. gr.87 - Air conditioning system  
GETth  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
1.2.19  
Quick-release coupling connections in  
refrigerant circuit  
Service connections with Schrader valve (needle valve or push  
pin)  
♦ Only valves and connections resistant to R1234yf refrigerant  
and the related refrigerant oils may be used.  
♦ Service connections -C- and -F- in an R1234yf refrigerant cir‐  
cuit are configured in such a way that service couplings cannot  
be connected to service connections designed for an R134a  
refrigerant circuit.  
♦ Different connections (external diameter) for high pressure  
and low pressure side -C- and -F-.  
♦ Before removing the valves or valve inserts -B- and -E-, empty  
the refrigerant circuit.  
♦ Always screw on sealing caps -A- and -D- with seal -G-.  
Layout in vehicle ⇒ Heating, air conditioning; Rep. gr. 87 ; Re‐  
frigerant circuit (vehicle-specific workshop manual).  
– Extract refrigerant before unscrewing the valves.  
♦ Service connection, low pressure side -F-  
♦ Service connection, high pressure side -C-  
♦ Valve insert (designation: Schrader or needle valve)  
♦ Sealing cap for service connection on low pressure side with  
seal -A-  
♦ Sealing cap for service connection on high pressure side with  
seal -D-  