Air conditioning system -> 1.2.17 High-pressure safety valve for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
1.2.17  
High-pressure safety valve  
The high pressure safety valve is fitted to the air conditioner com‐  
pressor or the receiver.  
The valve opens at a pressure of approx. 38 bar (overpressure)  
and closes again when the pressure has dropped (to approx. 35  
bar).  
Not all the refrigerant is lost from the system.  
Note  
Depending on the version, a transparent plastic washer -B-  
may be attached to the high pressure safety valve -A- which  
breaks off as soon as the valve is actuated.  
Depending on the version of high pressure safety valve -A-, a  
cover -C- may also be pushed onto the high pressure safety  
valve -A-. Should the pressure in the refrigerant circuit actually  
rise above the opening pressure of the high pressure safety  
valve -A- and cause the valve to open, refrigerant will not es‐  
cape in one direction but scatter through the openings -D-  
beneath the cover -C- instead.  
If a high-pressure safety valve -A- needs to be renewed, the  
specified torque for the new valve (depending on the manu‐  
facturer and the version of the air conditioner compressor)  
must be observed when installing. Air conditioner compres‐  
sors manufactured by “Denso”, “Sanden” and “Valeo” are  
equipped with an O-ring seal (currently valid torque settings  
are: 10 Nm for “Denso” and “Zexel/Valeo” air conditioner com‐  
pressors, and 15 Nm for “Sanden” air conditioner compres‐  
sors). Air conditioner compressors manufactured by “Delphi”  
are fitted with an oil seal (currently valid torque setting: 15 Nm).  
lk  
Renewing seals (oil seals or O-rings) ⇒ Electronic parts cata‐  
logue .  
If a seal (oil seal or O-ring) fitted to the high-pressure safety  
valve is not available as a replacement part, the removed old  
part can be reused (as an exception to the general rule of using  
new seals only). The old seal, however, must always be  
checked for damage prior to installation. If any damage or de‐  
formation is detected on the old seal, it must be renewed with  
a commercially available new part ⇒ Electronic parts cata‐  
logue .  
After filling the refrigerant circuit, check the installed high-  
pressure safety valve for leaks using e.g. an electronic leak  
detector.  
1. Refrigerant circuit  
53  
GETth  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
1.2.18  
Non-return valves  
Non-return valves separate the refrigerant circuit into different  
areas ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit  
(vehicle-specific workshop manual).  
Note  
The non-return valve -3- shown in installed e.g. in the Audi Q7  
e-tron ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant  
circuit (vehicle-specific workshop manual).  
Non-return valves in the refrigerant circuit have a certain hold‐  
ing pressure in the direction of flow (approx. 0.1 bar or  
100 mbar). To ensure that the refrigerant circuit can be evac‐  
uated completely (residual pressure below 5 mbar), all of the  
electrically actuated valves must therefore be open.  
Depending on the version, the direction of flow may be indi‐  
cated by a sticker.  
lk  
54  
Rep. gr.87 - Air conditioning system  
GETth  