Air conditioning system -> 2.7 Bringing air conditioning system into service after charging for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
A larger leak in the refrigerant circuit can be detected, for ex‐  
ample, by pressurising the circuit to a maximum of 15 bar using  
cleaned and dried compressed air or nitrogen ⇒ page 124 . If  
the leak is large enough, the leakage point can be detected by  
sound as the gas escapes.  
The compressed air or nitrogen is introduced to the closed,  
empty refrigerant circuit via the service connection -B- to which  
through a quick-release coupling adapter -A- has been con‐  
nected.  
lk  
Screw the handwheel -C- into the quick-release coupling  
adapter -A- until the valve in the service connection -B- is  
completely open - do not over tighten the valve.  
The quick-release coupling adapter for service connection can  
be fitted e.g. with a modified charging hose -A- (for example  
with a M12 x 1.5-6G thread in accordance with SAE J639)  
depending on the thread of the quick-release coupling adapter  
and a suitable adapter -B- to connect to the workshop com‐  
pressed air system ⇒ page 259 . To ensure that no moisture,  
oil and dirt from the workshop compressed air system enter  
the refrigerant circuit of the air conditioning system, use e.g. a  
combination fine filter unit for compressed air systems with an  
oil, dirt and water separator, which is commonly used in paint  
spraying facilities. Install this between the compressed air sys‐  
tem and the charge hose -A- ⇒ Electronic parts catalogue .  
Using the manifold gauge with pressure reducer for nitrogen  
(maximum reduced pressure: 15 bar) -1- you can connect a  
full nitrogen gas cylinder -3- via a charge hose -2- (e.g. with  
M12 x 1.5-6G thread in accordance with SAE J639) to the  
service connection - to which a quick-release coupling adapter  
is connected - of a closed, empty refrigerant circuit  
⇒ page 258 .  
– Slowly increase the pressure in the refrigerant circuit to a max‐  
imum of 15 bar.  
CAUTION  
Risk of injury from nitrogen escaping under high pressure.  
– Use pressure limiter for nitrogen tank.  
– Search for the leak by sound, which can be heard as gas es‐  
capes from this point.  
– Repair the leak.  
– Evacuate refrigerant circuit and observe the vacuum gauge  
over a period of hours. Only when a vacuum is maintained can  
charging commence.  
♦ If a leak is present of a size where no or very little air is drawn  
in - with the refrigerant circuit evacuated - and the air condi‐  
tioner service station can create sufficient vacuum. The vac‐  
uum gauge does not increase or increases very slowly after  
switching the air conditioner service station off. This indicates  
that there may be a very small ingress of air and the vacuum  
is lost.  
2. Working with air conditioner service station  
GETth  
145  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
– Charge the circuit with 100 g of refrigerant and search for the  
possible leak using an electronic leak tester  
⇒ “1.4.2 Searching for leaks in refrigerant circuits using an  
electronic leak detector”, page 69 or add an approved UV  
contrast substance to the refrigerant and search for the pos‐  
sible leak in the circuit using the leak detector system  
⇒ “1.4.3 Searching for leaks with UV leak detection system”,  
page 71 .  
– Evacuate refrigerant circuit if necessary  
⇒ “2.4 Emptying refrigerant circuit”, page 137  
– Rectify the problem in the refrigerant circuit ⇒ Heating, air  
conditioning; Rep. gr. 87 ; Refrigerant circuit (vehicle-specific  
workshop manual).  
– Evacuate the refrigerant circuit and observe the vacuum  
gauge over an extended period. Only when a vacuum is main‐  
tained can charging commence  
lk  
⇒ “2.5 Evacuating refrigerant circuit”, page 140 .  
If it is necessary after evacuating to perform work on the vehicle  
for which the air conditioner service station is not required:  
– Detach the air conditioner service station from the refrigerant  
circuit and switch off  
⇒ “2.8 Switching off air conditioner service station and sepa‐  
rating from refrigerant circuit”, page 151 .  
NOTICE  
Risk of damage to air conditioner compressor with negative  
pressure in the refrigerant circuit.  
– Never start the engine if there is negative pressure in the  
refrigerant circuit.  
– Ensure that, until the refrigerant circuit is charged, the engine  
cannot be started.  
If after emptying and evacuating the refrigerant circuit is to be  
recharged ⇒ “2.6 Charging refrigerant circuit”, page 146 .  
2.6  
Charging refrigerant circuit  
Note  
The whole amount of refrigerant can be charged either on the  
high pressure side or the low pressure side. Charging of the  
refrigerant circuit is described as follows for the high pressure  
side.  
Fill capacities of refrigerant and refrigerant oil ⇒ Heating, air  
conditioning; Rep. gr. 00 ; Technical data .  
The procedure described in the instruction manual for the air  
conditioning service station is to be followed ⇒ Operating in‐  
structions of air conditioner service station .  
Before charging the system with refrigerant, the amount of re‐  
frigerant oil must be adjusted ⇒ Heating, air conditioning; Rep.  
gr. 00 ; Technical data .  
Ensure when charging the refrigerant circuit that the air con‐  
ditioner service station is at the same level as the vehicle  
whose refrigerant circuit is to be charged (no greater than 50  
cm difference). If the height difference is too great, deviations  
may occur between the amount of refrigerant displayed and  
the amount actually charged (depending on the version of air  
146  
Rep. gr.87 - Air conditioning system  
GETth  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
lk  
conditioner service station ). The filling accuracy of the air  
conditioner service station may be affected.  
The refrigerant circuit is completely assembled ⇒ Heating, air  
conditioning; Rep. gr. 87 ; Refrigerant circuit; System over‐  
view - refrigerant circuit .  
– On vehicles with high-voltage system, switch off stationary air  
conditioning function (deactivate) ⇒ Owner's Manual .  
– Switch off ignition.  
– Connect the air conditioner service station to the power sup‐  
ply.  
– Check the volume of refrigerant, the volume of refrigerant oil  
and the amount of UV leak detection additive in the air condi‐  
tioner service station and replenish as necessary ⇒ Operating  
instructions air conditioner service station .  
In addition for vehicles with electrically-actuated valves in the re‐  
frigerant circuit that are not open when de-energised:  
Note  
On vehicles with high-voltage system and auxiliary air condition‐  
ing system functions (“heat pump mode” or “cooling of high-  
voltage battery”), valves may be installed in the refrigerant circuit  
that are not open when de-energised. These valves are opened  
and closed e.g. via incremental motors and are no longer actu‐  
ated when the ignition is switched off. To empty the refrigerant  
circuit completely or to evacuate and charge it correctly, however,  
no areas must be isolated. Therefore, these valves must be  
opened before performing these types of work ⇒ Heating, air  
conditioning; Rep. gr. 87 ; Refrigerant circuit (vehicle-specific  
workshop manual) and ⇒ Vehicle diagnostic tester in “Guided  
Fault Finding” mode.  
– Use the vehicle diagnostic tester to open the electrically-ac‐  
tuated valves that are not open when de-energised ⇒ Vehicle  
diagnostic tester in “Guided Fault Finding” mode.  
All vehicles  
– Bring the air conditioner service station into operation as de‐  
scribed in the instructions ⇒ Operating instructions air condi‐  
tioner service station .  
– Unscrew the sealing caps from the service connections of the  
refrigerant circuit (see vehicle-specific refrigerant circuit) ⇒  
Heating, air conditioning system; Rep. gr. 87 ; Refrigerant cir‐  
cuit (vehicle-specific workshop manual).  
– Connect quick-release couplings to the service connections of  
the refrigerant circuit  
⇒ “2.2 Connecting air conditioner service station to refrigerant  
circuit”, page 131 .  
– Evacuate the refrigerant circuit with the air conditioner service  
station ⇒ “2.5 Evacuating refrigerant circuit”, page 140 .  
– Adjust the requisite amount of refrigerant, the amount of re‐  
frigerant oil to be replenished if necessary and the amount of  
UV leak detection additive in the air conditioner service station  
⇒ Operating instructions air conditioner service station , ⇒  
Heating, air conditioning; Rep. gr. 00 ; Technical data (vehicle-  
specific workshop manual).  
– Choose the relevant setting on the air conditioner service sta‐  
tion for charging on the high pressure side ⇒ Operating  
instructions air conditioner service station .  
2. Working with air conditioner service station  
GETth  
147  