Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017
1.4.3
Searching for leaks with UV leak detec‐
tion system
Note
♦ Certain leaks are difficult or impossible to find using an elec‐
tronic leak detection device. To investigate these leaks, leak
detection can be performed using the leak detection system
⇒ Electronic parts catalogue .
♦ Refrigerant and refrigerant oil leaks out of the refrigerant circuit
when the circuit has a leak. This oil generally remains in the
vicinity of the leak location. To make the oil visible underlUk V
light, a small amount of fluorescent fluid must be added to the
refrigerant circuit. This fluid (PAG oil with an additive which
lights up under UV light) is injected into the refrigerant circuit
and distributed with the refrigerant oil when the air conditioning
system is switched on.
♦ The air conditioning system must be operated for at least
60 minutes to ensure that the injected leak detecting additive
is distributed throughout the entire refrigerant circuit (air con‐
ditioner compressor must run). The leak may become visible
under UV light after a short period, but this depends on the
size of the leak.
♦ The refrigerant oil with additive, which lights up under UV light,
can be added directly in an open circuit or charged after emp‐
tying the circuit with air conditioner service station via the
service connection.
♦ If the leak detection additive is added to the refrigerant circuit
via the service connection, a small amount of leak detection
additive will be deposited in the service connection. Carefully
remove any deposits so that this area is not mistaken for a leak
during subsequent leak detection.
♦ If a component from a circuit in which leak detection additive
is filled is renewed, thoroughly clean the connection points to
other components after assembling the refrigerant circuit. Dur‐
ing subsequent leak detection, deposits of leak detection ad‐
ditive could otherwise be mistaken for leaks at the connecting
point.
♦ When purging the refrigerant circuit, refrigerant oil and there‐
fore also leak detection additive also enter the air conditioner
service station . The refrigerant oil is separated from the re‐
frigerant in the oil separator of the air conditioner service
station and removed from the air conditioner service station
via the drainage outlet. The drained refrigerant oil may not be
reused. It must be replaced with fresh refrigerant oil.
♦ If leak detection fluid was injected during a previous repair of
the refrigerant circuit, observe the following: do not inject new
leak detection fluid unless the refrigerant machine oil has been
replaced. If only some of the refrigerant machine oil was re‐
placed then only the respective amount of leak detection fluid
should be injected. If, for example, 100 ml of refrigerant oil is
replaced in a vehicle with 250 ml of refrigerant oil, inject only
1 ml (cm3) of leak detection additive.
♦ Certain materials and their compounds (e.g. oxidisation prod‐
ucts on components made from aluminium, corrosion protec‐
tion wax, etc.) also light up under UV light.