Air conditioning system -> 1.4.4 Detecting leaks in a vacuum test using air conditioner service station, or in a pressure test for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
The amount of UV leak detection additive to be charged in the  
refrigerant circuit with a refrigerant oil volume up to 150 cm3  
is 3.0 ± 0.5 ml. If the volume of refrigerant oil in the refrigerant  
circuit is greater, more UV leak detection additive must be  
added accordingly, e.g. 5.0 ± 0.5 ml in a refrigerant circuit with  
a refrigerant oil volume of 250 cm3. If the UV leak detection  
additive is filled with an air conditioner service station , the  
volume to be set in your air conditioner service station may  
differ. Therefore, observe the relevant operating instructions  
⇒ Operating instructions Air conditioner service station .  
For the specific volume of refrigerant oil in the refrigerant cir‐  
cuit, refer to the vehicle-specific workshop manual ⇒ Heating,  
air conditioning; Rep. gr. 00 ; Technical data .  
If leak UV leak detection additive was injected during a previ‐  
ous repair of the refrigerant circuit, observe the following: do  
not inject new UV leak detection additive unless the refrigerant  
machine oil has been replaced. If only some of the refrigerant  
machine oil was replaced then only the respective amount of  
UV leak detection additive should be injected. If, for example,  
50 ml of refrigerant oil is replaced in a vehicle with 150 ml of  
refrigerant oil, inject only 1.0 ml (cm3) of UV leak detection  
additive.  
The leak detection system comprises the following parts:  
♦ Cleaning agent -3-  
♦ UV leak detection lamp -4-  
♦ UV absorbing eye protection -5-  
lk  
♦ Sticker -6-  
♦ Gloves -8-  
Note  
Items -1-, -2- and -7- in the diagram can be disregarded.  
Special tools and workshop equipment required  
♦ Leak detecting system  
♦ Air conditioner service station with means of adding UV leak  
detection additive in the refrigerant circuit ⇒ Electronic parts  
catalogue .  
♦ Approved leak detection additive ⇒ Electronic parts cata‐  
logue .  
– Evacuate the refrigerant circuit as per the instructions, and  
charge the system with UV leak detection additive and refrig‐  
erant ⇒ “2.5 Evacuating refrigerant circuit”, page 140 and  
⇒ “2.6 Charging refrigerant circuit”, page 146 .  
– Wait until the pressures on the high pressure and low pressure  
side have settled.  
1. Refrigerant circuit  
73  