Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
1.2.23  
Air conditioner compressor regulating  
valve - N280-  
Note  
Refer to vehicle-specific refrigerant circuit for switching pres‐  
sures, removing and installing switches and location/design of  
switches ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant  
circuit; System overview - refrigerant circuit .  
♦ The regulating valve is fitted to the air conditioner compressor.  
It is actuated, for example, by the air conditioning system con‐  
trol unit - J301- , the operating and display unit for front air  
conditioning system - E87- or the Climatronic control unit -  
J255- (potentially also via data bus and an additional control  
unit depending on the vehicle) ⇒ Vehicle diagnostic tester in  
“Guided Fault Finding” mode - air conditioning system and ⇒  
lk  
Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit (ve‐  
hicle-specific workshop manual).  
♦ The regulating valve influences the pressure on the low pres‐  
sure side and thus the temperature at the evaporator.  
Note  
The air conditioner compressor regulating valve - N280- is an in‐  
tegral part of the air conditioner compressor and cannot be re‐  
newed individually on all air conditioner compressors ⇒  
Electronic parts catalogue .  
1.2.24  
Refrigerant temperature sender  
Note  
A refrigerant temperature sender (a temperature sender that  
does not evaluate the pressures) is currently not used by  
Volkswagen/Audi.  
Switching pressures, removing and installing switches and  
switch layout and design ⇒ Vehicle diagnostic tester in “Gui‐  
ded Fault Finding” mode - air conditioning system and ⇒  
Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit (ve‐  
hicle-specific workshop manual).  
1. Refrigerant circuit  
63  
GETth  

Related Topics

1 Refrigerant circuit 1.1 System overview - refrigerant circuit 1.1.1 System overview - refrigerant circuit with expansion valve and receiver 1.1.2 System overview - refrigerant circuit with restrictor and reservoir 1.1.3 System overview - refrigerant circuit with electrically driven air conditioner compressor 1.2 General description - components of refrigerant circuit 1.2.1 Layout and function of refrigerant circuit 1.2.2 Mechanical air conditioner compressor 1.2.3 Electrical air conditioner compressor for hybrid vehicles 1.2.4 Condenser 1.2.5 Evaporator 1.2.6 Reservoir 1.2.7 Heat exchanger for heat pump mode 1.2.8 Liquid receiver 1.2.9 Restrictor 1.2.10 Receiver 1.2.11 Expansion valve (with and without shut-off valve) 1.2.12 Refrigerant shut-off valves 1.2.13 Refrigerant line with internal heat exchanger 1.2.14 Quick release couplings of refrigerant lines 1.2.15 Seals 1.2.16 Pipes and hoses in refrigerant circuit 1.2.17 High-pressure safety valve 1.2.18 Non-return valves 1.2.19 Quick-release coupling connections in refrigerant circuit 1.2.20 Connections with valve for switches in refrigerant circuit 1.2.21 Pressure senders and switches in refrigerant circuit 1.2.22 Refrigerant pressure and temperature sender 1.2.24 Refrigerant temperature sender 1.3 Possible complaints 1.3.1 Prerequisites for investigating a complaint 1.3.2 Possible complaints 1.3.3 Odours from heater and air conditioner unit 1.4 Investigating leaks 1.4.1 General information about investigating leaks in the refrigerant circuit 1.4.2 Searching for leaks in refrigerant circuits using an electronic leak detector 1.4.3 Searching for leaks with UV leak detection system 1.4.4 Detecting leaks in a vacuum test using air conditioner service station, or in a pressure test 1.4.5 Detecting leaks in a pressure test (with nitrogen or compressed air) 1.5 Renewing components 1.5.1 General information about renewing components 1.5.2 Renewing leaking or damaged components of empty refrigerant circuit 1.5.3 Renewing leaking or damaged components of charged refrigerant circuit 1.5.4 Renewing air conditioner compressor with no need to clean refrigerant circuit 1.5.5 Renewing air conditioner compressor due to leaks or internal damage 1.5.6 Renewing desiccant cartridge / receiver after cleaning refrigerant circuit 1.5.7 Renewing receiver with no need to clean refrigerant circuit 1.5.8 Renewing desiccant cartridge / desiccant bag with no need to clean refrigerant circuit 1.6 Cleaning refrigerant circuit 1.6.1 General information about cleaning refrigerant circuit 1.6.2 Preparations for cleaning refrigerant circuit (flushing with R1234yf refrigerant) 1.6.3 Refrigerant circuit cleaning procedure 1.6.4 Principle circuit diagrams for cleaning (flushing circuits) - refrigerant circuit with expansion valve and receiver 1.6.5 Principle circuit diagrams for cleaning (flushing circuits) - refrigerant circuit with restrictor and receiver 1.6.6 Principle circuit diagrams for cleaning (flushing circuits) - vehicles with high-voltage system (without auxiliary) 1.6.7 Principle circuit diagrams for cleaning (flushing circuits) - vehicles with high-voltage system (with auxiliary) 1.6.8 Adapters for setting up flushing circuits 1.6.9 General information about blowing through with compressed air or nitrogen 1.6.10 Blowing through refrigerant circuit with compressed air or nitrogen 1.7 Checking pressures with pressure gauge 1.7.1 Display on pressure gauges 1.7.2 Pressure gauges enable the following test and measurement work 2 Working with air conditioner service station 2.1 Working with air conditioner service station 2.2 Connecting air conditioner service station to refrigerant circuit 2.3 Performing gas analysis of refrigerant 2.4 Emptying refrigerant circuit 2.5 Evacuating refrigerant circuit 2.6 Charging refrigerant circuit 2.7 Bringing air conditioning system into service after charging 2.8 Switching off air conditioner service station and separating from refrigerant circuit 2.9 Charging refrigerant in reservoir 2.10 Emptying air conditioner service station 2.11 Cleaning electrical air conditioning compressor 2.12 Cleaning refrigerant circuit 2.13 Filling contaminated refrigerant in a recycling cylinder for analysis, processing or disposal 2.13.1 Filling contaminated refrigerant in a recycling cylinder using technical equipment 2.13.2 Filling undercooled contaminated refrigerant in a recycling cylinder 2.14 Checking pressures 2.14.1 General information on checking pressures in the refrigerant circuit 2.14.2 Pressures and temperatures in refrigerant circuit 2.14.3 Checking pressures in the refrigerant circuit with the ignition switched off 2.14.4 Checking pressures with air conditioning system switched on - vehicles with mechanical air conditioning compressor 2.14.5 Checking pressures with air conditioning system switched on - vehicles with electrical air conditioning compressor 3 Testing equipment and tools 3.1 Tools and materials available from distribution centre or importer 3.2 Tools and materials available commercially 3.3 Tools that can be locally manufactured