2015-2022 Volkswagen Touran 4 Door Air conditioning system -> 3.2 Tools and materials available commercially User Manual
MyCarUserManual.com
USER MANUALS FOR EVERY MAKE & MODEL

Air conditioning system -> 3.2 Tools and materials available commercially for Your Volkswagen Touran 4 Door Second Generation (2015-2022)

Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Note  
The cause of this fault could also be too much refrigerant oil  
in the circuit. Overfilling with refrigerant oil can occur if the re‐  
frigerant oil level was not checked after the air conditioner  
compressor was renewed.  
Further notes regarding this ⇒ page 241 .  
Possible deviation from specification during pressure test  
High pressure and low pressure normal  
The requisite cooling output in the evaporator of the heating and air conditioning unit and in the evaporator  
lk  
for cooling the high-voltage components is not reached.  
or  
High pressure and low pressure normal  
The air conditioner compressor is noisy (especially immediately after being switched on)  
The requisite cooling output in the evaporator of the heating and air conditioning unit (and/or in the evap‐  
orator used to cool the high-voltage components) is not reached.  
Possible causes for deviation from specification and rectification  
♦ One of the pressure/temperature senders or temperature sensors on or in the refrigerant circuit supplies  
incorrect values ⇒ Vehicle diagnostic tester in “Guided Fault Finding” mode and ⇒ Heating, air conditioning;  
Rep. gr. 87 ; Overview of fitting locations - air conditioning system  
♦ Actuation and function of air conditioner compressor faulty ⇒ Vehicle diagnostic tester in “Guided Fault  
Finding” mode.  
♦ One of the valves installed in the refrigerant circuit is defective or is not working properly ⇒ Heating, air  
conditioning; Rep. gr. 87 ; Refrigerant circuit (vehicle-specific workshop manual).  
♦ Too much refrigerant in circuit.  
♦ Expansion valve for the evaporator in the front heating and air conditioning unit defective.  
♦ Too much refrigerant oil in circuit.  
– Check the measured values of the various pressure/temperature senders and temperature sensors during  
operation of the air conditioning system, renew components with false measured values ⇒ Vehicle diag‐  
nostic tester in “Guided Fault Finding” mode and ⇒ Heating, air conditioning; Rep. gr. 87 ; Overview of  
fitting locations - air conditioning system .  
– Check the actuation and function of the air conditioner compressor and repair ⇒ Vehicle diagnostic tester  
in “Guided Fault Finding” mode  
– Check the function and actuation of the various valves and pressure/temperature senders installed in the  
refrigerant circuit by means of the pressure distribution in the refrigerant circuit ⇒ Vehicle diagnostic tester  
in “Guided Fault Finding” mode and ⇒ Heating, air conditioning; Rep. gr. 87 ; Refrigerant circuit (vehicle-  
specific workshop manual).  
– If no fault can be found, extract the refrigerant from the refrigerant circuit.  
The quantity of refrigerant extracted is significantly greater than the prescribed charge quantity:  
– Recharge the refrigerant circuit and repeat the test.  
The quantity of refrigerant extracted is about equal to the prescribed charge quantity:  
– Clean the refrigerant circuit (flush with R1234yf refrigerant ⇒ “1.6 Cleaning refrigerant circuit”, page 92 ).  
– Pour in the correct amount of refrigerant oil in the circuit (see note).  
Final measures  
254  
Rep. gr.87 - Air conditioning system  
GETth  
Arteon 2018 ➤ , Atlas 2017 ➤ , CC 2012 ➤ , Caddy 2016 ➤ , Crafter 201 ...  
Air conditioning systems with refrigerant R1234yf - General information - Edition 07.2017  
Possible deviation from specification during pressure test  
– Recharge the refrigerant circuit ⇒ “2.6 Charging refrigerant circuit”, page 146  
– Repeat test  
⇒ “2.14.5 Checking pressures with air conditioning system switched on - vehicles with electrical air condi‐  
tioning compressor”, page 205  
lk  
Note  
Overfilling with refrigerant oil can occur if the refrigerant oil  
level was not checked after the air conditioner compressor  
was renewed.  
If e.g. the expansion valve for the evaporator in the heating  
and air conditioning unit or for the evaporator used to cool the  
high-voltage components is defective (always open), the  
evaporator temperature (in the front heating and air condition‐  
ing unit) is no longer regulated in such a way that only gaseous  
refrigerant exits the evaporator. It is then possible that under  
certain operating conditions, drops of liquid will be drawn into  
the air conditioner compressor, which will hen cause noise  
(because liquid is incompressible).  
If there is too much refrigerant in the refrigerant circuit, the air  
conditioner compressor must be emptied and the receiver re‐  
newed. After cleaning the refrigerant circuit (flushing with  
R1234yf refrigerant)  
⇒ “1.6 Cleaning refrigerant circuit”, page 92 , pour the correct  
amount of refrigerant oil in the circuit ⇒ Heating, air condi‐  
tioning; Rep. gr. 00 ; Technical data (vehicle-specific work‐  
shop manual).  
Further notes regarding this ⇒ page 241 .  
Possible deviation from specification during pressure test  
High pressure and low pressure normal  
The requisite cooling output in the evaporator of the front heating and air conditioning unit (and in the  
evaporator for cooling the high-voltage components) is not reached.  
The requisite cooling output is not reached in the heat exchanger for heat pump operation.  
Possible causes for deviation from specification and rectification  
2. Working with air conditioner service station  
GETth  
255  

Related Topics

1 Refrigerant circuit 1.1 System overview - refrigerant circuit 1.1.1 System overview - refrigerant circuit with expansion valve and receiver 1.1.2 System overview - refrigerant circuit with restrictor and reservoir 1.1.3 System overview - refrigerant circuit with electrically driven air conditioner compressor 1.2 General description - components of refrigerant circuit 1.2.1 Layout and function of refrigerant circuit 1.2.2 Mechanical air conditioner compressor 1.2.3 Electrical air conditioner compressor for hybrid vehicles 1.2.4 Condenser 1.2.5 Evaporator 1.2.6 Reservoir 1.2.7 Heat exchanger for heat pump mode 1.2.8 Liquid receiver 1.2.9 Restrictor 1.2.10 Receiver 1.2.11 Expansion valve (with and without shut-off valve) 1.2.12 Refrigerant shut-off valves 1.2.13 Refrigerant line with internal heat exchanger 1.2.14 Quick release couplings of refrigerant lines 1.2.15 Seals 1.2.16 Pipes and hoses in refrigerant circuit 1.2.17 High-pressure safety valve 1.2.18 Non-return valves 1.2.19 Quick-release coupling connections in refrigerant circuit 1.2.20 Connections with valve for switches in refrigerant circuit 1.2.21 Pressure senders and switches in refrigerant circuit 1.2.22 Refrigerant pressure and temperature sender 1.2.23 Air conditioner compressor regulating valve N280 1.2.24 Refrigerant temperature sender 1.3 Possible complaints 1.3.1 Prerequisites for investigating a complaint 1.3.2 Possible complaints 1.3.3 Odours from heater and air conditioner unit 1.4 Investigating leaks 1.4.1 General information about investigating leaks in the refrigerant circuit 1.4.2 Searching for leaks in refrigerant circuits using an electronic leak detector 1.4.3 Searching for leaks with UV leak detection system 1.4.4 Detecting leaks in a vacuum test using air conditioner service station, or in a pressure test 1.4.5 Detecting leaks in a pressure test (with nitrogen or compressed air) 1.5 Renewing components 1.5.1 General information about renewing components 1.5.2 Renewing leaking or damaged components of empty refrigerant circuit 1.5.3 Renewing leaking or damaged components of charged refrigerant circuit 1.5.4 Renewing air conditioner compressor with no need to clean refrigerant circuit 1.5.5 Renewing air conditioner compressor due to leaks or internal damage 1.5.6 Renewing desiccant cartridge / receiver after cleaning refrigerant circuit 1.5.7 Renewing receiver with no need to clean refrigerant circuit 1.5.8 Renewing desiccant cartridge / desiccant bag with no need to clean refrigerant circuit 1.6 Cleaning refrigerant circuit 1.6.1 General information about cleaning refrigerant circuit 1.6.2 Preparations for cleaning refrigerant circuit (flushing with R1234yf refrigerant) 1.6.3 Refrigerant circuit cleaning procedure 1.6.4 Principle circuit diagrams for cleaning (flushing circuits) - refrigerant circuit with expansion valve and receiver 1.6.5 Principle circuit diagrams for cleaning (flushing circuits) - refrigerant circuit with restrictor and receiver 1.6.6 Principle circuit diagrams for cleaning (flushing circuits) - vehicles with high-voltage system (without auxiliary) 1.6.7 Principle circuit diagrams for cleaning (flushing circuits) - vehicles with high-voltage system (with auxiliary) 1.6.8 Adapters for setting up flushing circuits 1.6.9 General information about blowing through with compressed air or nitrogen 1.6.10 Blowing through refrigerant circuit with compressed air or nitrogen 1.7 Checking pressures with pressure gauge 1.7.1 Display on pressure gauges 1.7.2 Pressure gauges enable the following test and measurement work 2 Working with air conditioner service station 2.1 Working with air conditioner service station 2.2 Connecting air conditioner service station to refrigerant circuit 2.3 Performing gas analysis of refrigerant 2.4 Emptying refrigerant circuit 2.5 Evacuating refrigerant circuit 2.6 Charging refrigerant circuit 2.7 Bringing air conditioning system into service after charging 2.8 Switching off air conditioner service station and separating from refrigerant circuit 2.9 Charging refrigerant in reservoir 2.10 Emptying air conditioner service station 2.11 Cleaning electrical air conditioning compressor 2.12 Cleaning refrigerant circuit 2.13 Filling contaminated refrigerant in a recycling cylinder for analysis, processing or disposal 2.13.1 Filling contaminated refrigerant in a recycling cylinder using technical equipment 2.13.2 Filling undercooled contaminated refrigerant in a recycling cylinder 2.14 Checking pressures 2.14.1 General information on checking pressures in the refrigerant circuit 2.14.2 Pressures and temperatures in refrigerant circuit 2.14.3 Checking pressures in the refrigerant circuit with the ignition switched off 2.14.4 Checking pressures with air conditioning system switched on - vehicles with mechanical air conditioning compressor 2.14.5 Checking pressures with air conditioning system switched on - vehicles with electrical air conditioning compressor 3 Testing equipment and tools 3.1 Tools and materials available from distribution centre or importer 3.3 Tools that can be locally manufactured